Exciting enhancements are coming soon to eCode360! Learn more 🡪
Township of Mansfield, NJ
Warren County
By using eCode360 you agree to be legally bound by the Terms of Use. If you do not agree to the Terms of Use, please do not use eCode360.
Table of Contents
Table of Contents
A. 
Site lighting shall be provided in all areas accessible to the public in accordance with the following table:
Area
Average Maintained Footcandles
Parking lots:
Shopping centers
1.5 to 5.0
Retail businesses
1.0 to 4.0
Industrial
0.5 to 1.0
Residential, multifamily
0.4 to 1.0
Access driveways:
Shopping centers
2.0 to 3.0
Retail businesses
1.0 to 3.0
Industrial
1.0 to 3.0
Residential, multifamily
0.6 to 1.0
Parking areas and pedestrian ways
0.4
Sidewalks
0.5
Intersections
2.0 to 5.0
Other areas
As determined by individual study
B. 
In general, the areas most frequently utilized shall be more intensely lit, with lighting levels decreasing as usage decreases.
All lighting shall be designed to meet the following minimum criteria:
A. 
All lighting from fixtures shall be cut off at property lines adjoining residential areas and zones.
B. 
Fixtures shall provide cutoff so that the lamp or refractor is not visible from adjoining roadways or residential areas.
C. 
Sky glow effects shall be prohibited.
D. 
Maximum desirable luminaire mounting heights shall be 30 feet.
E. 
A minimum uniformity ratio shall vary from six to one for the intensely lit areas to 10 to one for the remote areas. The uniformity ratio shall be the ratio of the average to minimum intensity.
Streetlighting shall be guided by the following minimum requirements:
Street Class
Minimum Average Maintained Footcandles
Uniformity
(average to minimum)
Major collector
0.5
6:1
Minor collector
0.3
Local
0.2