[Ord. 29, 9/24/1973, § 1012.1]
1. Natural gas piping systems when installed in mobile home parks shall
be approved by the utility company providing the service.
2. Each mobile home lot provided with piped gas shall have an approved
shutoff valve installed upstream of the gas outlet. The outlet shall
be equipped with an approved cap to prevent accidental discharge of
gas when the outlet is not in use.
[Ord. 29, 9/24/1973, § 1012.2]
1. Liquefied petroleum gas systems provided for mobile homes, service
buildings or other structures when installed shall be maintained in
conformity with any applicable rules and regulations and shall include
the following:
A. Systems shall be provided with safety devices to relieve excessive
pressures and shall be arranged so that the discharge terminates at
a safe location.
B. Systems shall have at least one accessible means for shutting off
gas. Such means shall be located outside the mobile home and shall
be maintained in effective operating condition.
C. All LPG piping outside of the mobile homes shall be buried and protected
against mechanical injury. Undiluted liquefied petroleum gas in liquid
form shall not be conveyed through piping equipment and systems in
mobile homes.
D. No LPG vessel shall be stored or located inside or beneath any storage
cabinet, carport, mobile home or any other structure unless such installations
are specially approved by the Township.
[Ord. 29, 9/24/1973, § 1012.3]
1. All fuel oil supply systems provided for mobile homes, service buildings
and other structures shall be installed and maintained in conformity
with any applicable rules and regulations.
2. All storage tanks shall be protected from physical damage.
3. All fuel oil supply systems provided for mobile homes, service buildings
and other structures shall have shut-off valves located within five
inches of storage tanks.
4. All fuel storage tanks and cylinders shall be securely placed and
under no circumstances located less than five feet from any mobile
home exit.