Exciting enhancements are coming soon to eCode360! Learn more 🡪
Village of Irvington, NY
Westchester County
By using eCode360 you agree to be legally bound by the Terms of Use. If you do not agree to the Terms of Use, please do not use eCode360.
Table of Contents
Table of Contents
[Added 6-26-2003 by L.L. No. 9-2003]
A. 
The unique character of residential neighborhoods in Irvington rests on the diversity in the style and design of houses as well as the general uniformity in the scale of houses located on similarly sized lots in neighborhoods throughout the community. The recent trend of tearing down existing houses and replacing them with larger houses or building large additions to existing houses threatens the appearance and impacts upon the health, safety, welfare, and quality of life in Irvington.
B. 
This article establishes a maximum floor area ratio (FAR) for all homes in Irvington. It responds both to the desire of residents to enlarge their homes to meet the needs of their families and to preserve neighborhood character by requiring houses to appear to be of the same or similar scale to others in the neighborhood. It is the intent of this article to encourage both new houses and expansions or alterations to existing houses to have a consistent scale with the nearby residences on both sides of the street. The FAR provisions are intended to be applied together with other provisions of the Village Zoning Code, including the provisions for lot coverage and resource protection.
Words used in this article shall have the meanings indicated in Chapter 224, Zoning, and, in addition thereto, the following terms shall have the meanings indicated:
DECK
An outdoor platform attached to the principal structure of a building and built above the natural grade. A deck does not have a roof and is exposed to the elements.
GROSS FLOOR AREA
The sum of the gross area of all floors of a residence, measured to the exterior of the outside walls. In calculating the gross floor area of houses for the purpose of calculating floor area ratio (FAR), all floor areas of each floor of all principal and all accessory structures on the lot shall be included, except for the portion which may be exempted as provided in § 224-137. Any interior space with a floor-to-ceiling height in excess of 12 feet shall be counted twice.
HEIGHT, FLOOR-TO-CEILING
The distance between the finished floor and the finished ceiling of an interior space. The distance shall be equal to the length of a theoretical line drawn from the floor to a point of the highest portion of the ceiling directly above it and is perpendicular to the horizontal plane of the floor.
OUT-OF-SCALE
With regard to a building or any part thereof, the condition of being or appearing to be disproportionately large, bulky, or massive relative to the other buildings in the surrounding neighborhood (particularly, but not limited to, the buildings on contiguous tax lots) and/or relative to the size of the tax lot upon which the building is situated; also, with regard to any one part of a building (or an addition to a preexisting building), the condition of being or appearing to be disproportionately large, bulky, or massive relative to any other part of the same building (or, in the case of an addition, relative to the preexisting building); with regard to an accessory structure, the condition of being or appearing to be disproportionately large, bulky, or massive relative to the principal structure, the other buildings in the surrounding neighborhood, and/or the size of the tax lot upon which the accessory structure is situated.
PORCH, ENCLOSED
A structure attached to a building, with a floor, roof, and structural supports, and permanently, seasonally, or temporarily enclosed with solid materials, such as glass or lexan (a clear, durable, hard plastic material). Screens, curtains, or latticework made of wire-mesh, cloth, paper, strips of wood or metal, or other similar material, shall not be considered “solid” for the purpose of this definition. A porch does not need to be heated or insulated to be considered enclosed.
PORCH, UNENCLOSED
A structure attached to a building, which has a floor, a roof, and structural supports, but not permanently, seasonally, or temporarily enclosed with solid materials such as glass or lexan (a clear, durable, hard plastic material).
A. 
As illustrated below, the maximum permitted floor area ratio (FAR) and resulting maximum residential floor area for houses shall be as follows:
Lot Size
(square feet)
Maximum FAR
Residential Floor Area
(square feet)
5,000*
0.43
2,150
6,000
0.39
2,340
7,000
0.36
2,520
8,000
0.33
2,640
9,000
0.3
2,700
10,000
0.28
2,800
11,000
0.2725
2,998
12,000
0.265
3,180
13,000
0.2575
3,348
14,000
0.25
3,500
15,000
0.2425
3,638
16,000
0.235
3,760
17,000
0.2275
3,868
18,000
0.22
3,960
19,000
0.2125
4,038
20,000
0.2
4,000
21,000
0.198
4,158
22,000
0.196
4,312
23,000
0.194
4,462
24,000
0.192
4,608
25,000
0.19
4,750
26,000
0.188
4,888
27,000
0.186
5,022
28,000
0.184
5,152
29,000
0.182
5,278
30,000
0.18
5,400
31,000
0.178
5,518
32,000
0.176
5,632
33,000
0.174
5,742
34,000
0.172
5,848
35,000
0.17
5,950
36,000
0.168
6,048
37,000
0.166
6,142
38,000
0.164
6,232
39,000
0.162
6,318
40,000
0.1625
6,500
41,000
0.1605
6,581
42,000
0.1585
6,657
43,000
0.1565
6,730
44,000
0.1545
6,798
45,000
0.1525
6,863
46,000
0.1505
6,923
47,000
0.1485
6,980
48,000
0.1465
7,032
49,000
0.1445
7,081
50,000
0.1425
7,125
51,000
0.1405
7,166
52,000
0.1385
7,202
53,000
0.1365
7,235
54,000
0.1345
7,263
55,000
0.1325
7,288
56,000
0.1305
7,308
57,000
0.1285
7,325
58,000
0.1265
7,337
59,000
0.1245
7,346
60,000
0.125
7,500
61,000
0.125
7,625
62,000
0.125
7,750
63,000
0.125
7,875
64,000
0.125
8,000
65,000
0.125
8,125
66,000
0.125
8,250
67,000
0.125
8,375
68,000
0.125
8,500
69,000
0.125
8,625
70,000
0.125
8,750
71,000
0.125
8,875
72,000
0.125
9,000
73,000
0.125
9,125
74,000
0.125
9,250
75,000
0.125
9,375
76,000
0.125
9,500
77,000
0.125
9,625
78,000
0.125
9,750
79,000
0.125
9,875
80,000 and above
0.125
10,000
Notes: *For lots 5,000 square feet and under, the maximum FAR shall be 0.43.
B. 
Any house which exceeds 10,000 square feet of gross floor area shall be required to obtain a variance from the Zoning Board of Appeals.
A. 
Decks, patios, unenclosed porches and porticoes.
(1) 
All space in unroofed structures such as decks and patios shall be excluded from the calculation of FAR.
(2) 
All space in unenclosed porches and porticoes shall be excluded from the calculation of FAR. For the purpose of FAR calculation, “unenclosed” shall mean those porches or porticoes that are open and not permanently, seasonally or temporarily enclosed.
B. 
Basements, cellars and basement garages. Where the exposed exterior wall or walls of basement, cellar or basement garage(s) facing the front yard(s) is less than three feet (measured from the lower of existing grade prior to construction or grade after construction to the bottom of the floor above the basement) the proportionate share of the basement, cellar or basement garage(s) shall be excluded from the calculation of FAR. All the remaining portions of the floor area of basements, cellars or basement garages, where the height (as defined above) of the exterior exposed wall or walls facing the front yard is three feet or more, shall be included in the FAR.
(1) 
Note: The proportionate share is defined as the relationship between that portion of the basement, cellar, or basement garage(s) with an exposed exterior wall of less than three feet to the entire length to such exterior wall.
C. 
Attics shall be calculated as follows:
[Amended 6-20-2005 by L.L. No. 6-2005]
(1) 
Attics with access through a drop stair or hatch, with a height of less than seven feet six inches shall be excluded from the calculation of the FAR.
(2) 
Attics with access through a drop stair or hatch, with a height of seven feet six inches or greater, shall count as 50% of the FAR.
(3) 
An unfinished attic, with access from a staircase or door, with a height of less than seven feet six inches, shall count as 50% of the FAR.
(4) 
Attics, finished or unfinished, with an access from a staircase or door, with a height seven feet six inches or greater, shall count as 100% of the FAR.
(5) 
A finished attic shall count as 100% of the FAR.
D. 
Garages.
(1) 
On lots measuring 9,999 square feet or less, the lesser of 250 square feet or the total floor area contained within one-story garages, either detached or attached to the principal structure, shall be excluded from the calculation of FAR. On lots measuring 10,000 square feet or more, the lesser of 400 square feet or the total floor area contained within one-story garages, either detached or attached to the principal structure, shall be excluded from the calculation of FAR. In those instances where an additional story is provided above a garage, whether detached or attached, such floor area or the garage floor area, up to the limits set forth herein as defined by lot size, shall be excluded from the calculation of FAR.
(2) 
Notwithstanding the above, this section shall not apply to basement garages.
E. 
One shed, provided it does not have a paved foundation, does not exceed 64 square feet in area or 10 feet in height, and has no side longer than 10 feet.
[Added 5-16-2022 by L.L. No. 4-2022]
A. 
Upon receipt of a building permit application for a house, or upon the submission of an application for site development plan approval or waiver of site development plan approval, the Building Inspector shall determine whether the proposed application exceeds the allowable FAR prescribed under § 224-136.
[Amended 6-20-2005 by L.L. No. 6-2005]
B. 
Houses at or below the maximum FAR. If an application does not exceed the maximum FAR, the Building Department shall proceed with the building permit application and/or process the application for site development plan approval or waiver of site development plan approval for consideration by the Planning Board.
C. 
Residences above the maximum FAR. Applications for building permits, site development plan approval, or waiver of site development plan approval for residences whose total floor area, as of June 1, 2003, exceeds or is seeking approval for an application or permit which will exceed the maximum permitted FAR, shall be required to seek a variance from the Zoning Board of Appeals in accordance with Article XIX of the Irvington Zoning Code. In considering the variance application, the Zoning Board of Appeals shall consider, among other items, any design guidelines set forth in the Irvington Code. The Zoning Board of Appeals may also, at its discretion, refer the application to the Board of Architectural Review for an advisory opinion. Any application for a variance for FAR for a residence shall require the submission of the following additional materials, if available, in addition to those required for the building permit:
(1) 
Elevations (photos, drawings, scale) of the houses on all sides of the subject house, including across the street;
(2) 
Photographs of neighboring houses, structures, and yards within 200 feet on any side of the subject house, including across the street; and
(3) 
Floor area ratios of neighboring houses on lots within 200 feet on either side of the subject house.
(4) 
The applicant shall also provide written or verbal testimony addressing the proofs required for variances.
D. 
Additions to existing structures that exceed allowable FAR. When considering the FAR and out-of-scale components of an application for an addition where the preexisting structure exceeds the allowable FAR as set forth in § 224-136, the Zoning Board of Appeals may, in its discretion, consider the increase of that addition over the existing FAR of the preexisting structure, provided that the resulting structure is not out-of-scale with the surrounding neighborhood.
[Added 2-7-2005 by L.L. No. 3-2005]
A. 
This article shall apply to any application for a building permit that has not been submitted to the Building Department for consideration or processing, as of June 1, 2003.
B. 
For properties which have received final subdivision approval, this article shall not apply to any application for a lot which has been submitted for consideration or processing of final site development plan approval or waiver, as of June 1, 2003. All applications for limited or final site development plan approval, waiver of site development plan approval, or variances submitted subsequent to June 1, 2003, shall be subject to this article.