A. 
It shall be unlawful for any person whose premises are connected to the sanitary wastewater collection system owned and/or operated by the owner to permit, allow or cause to enter into such system any wastewater from any property other than that for which the sanitary connection permit was issued.
B. 
It shall be unlawful for any person whose premises are connected to the sanitary wastewater collection system owned and/or operated by the owner to permit, allow or cause to enter into such system any of the following pollutants, substances or wastewater:
(1) 
Pollutants which create a fire or explosive hazard in the sanitary wastewater collection system or the owner's wastewater treatment facility, including, but not limited to waste streams with a closed-up flashpoint of less than 140º F.;
(2) 
Wastewater having a pH less than 5.0, or otherwise causing corrosive structural damage to the sanitary wastewater collection system or the owner's wastewater treatment facility or other equipment, or endangering the owner's personnel;
(3) 
Solid or viscous substances in amounts which will cause obstruction of the flow in the owner's sanitary wastewater collection system;
(4) 
Petroleum oil, nonbiodegradable cutting oil or products of mineral oil origin, in amounts exceeding 100 mg/l as oil and grease in discharge or in amounts that will cause obstruction of the flow in the sanitary wastewater collection system or the owner's wastewater treatment facilities or which will cause pass-through at the treatment facility;
(5) 
Pollutants which result in the presence of toxic gases, vapors or fumes within the owner's sanitary wastewater collection system or its wastewater treatment facilities in a quantity that may cause worker health and/or safety problems; and
(6) 
Stormwater, surface water, groundwater, artesian-well water, roof runoff or subsurface drainage.
C. 
The manager or his designee, bearing proper identification, shall be permitted to enter the premises of any nondomestic discharger at any reasonable time for the purpose of inspection of facilities to ensure compliance with the provisions of this section.
All industrial dischargers of wastewater within the Borough of Clarion and which discharge industrial wastewater into the owner's sanitary wastewater collection system must comply with the provisions of the owner's industrial waste pretreatment regulations.
A. 
It shall be unlawful for any person to engage in the nondomestic preparation of food or the washing of dishes used to serve food for nondomestic consumption without a properly installed, operational and regularly maintained grease interceptor or grease trap system to separate, remove, collect and contain grease content from wastewater prior to the discharge of said wastewater into the sanitary wastewater collection system owned and/or operated by the owner. The grease interceptor or grease trap system shall be installed and maintained in accordance with the requirements of the owner.
B. 
The type of installation (either grease trap interceptor or grease trap system) shall be determined by the total fixture flow-through rate of potential grease-laden fixtures discharging through the building sanitary wastewater lines as determined in accordance with the International Code Council/International Plumbing Code, latest edition.
(1) 
For flow-through of 35 gallons per minute or less, an internal grease trap system is required.
(2) 
For flow-through rates in excess of 35 gpm, an external underground grease interceptor is required.
C. 
A grease interceptor or grease trap system shall be installed at an appropriate location along the building sanitary wastewater discharge system before the point of connection between the sanitary wastewater service line and public collection system. Said grease interceptor or grease trap system and its installation shall be in compliance with the rules, regulations, plans and specifications as established by the owner.
D. 
The grease interceptor or grease trap shall limit the amount of grease discharged into the public collection system to a level not to exceed 100 mg/l as oil and grease downstream of the interceptor or trap.
E. 
Where a grease interceptor is required, an inspection site tee shall be installed between the interceptor discharge point and the sanitary wastewater service line connection to the public collection system.
F. 
Grease interceptors and grease traps shall be maintained and kept in proper working order at all times in accordance with the rules, regulations and requirements as established by the owner. Records of all grease interceptors or grease trap system cleaning and/or maintenance shall be kept on the subject premises at all times and shall be available for review by the Manager or his designee.
G. 
No solid waste devices, such as waste grinders, disposals, potato peelers, etc., shall discharge through a grease trap or grease interceptor. Only potential grease-laden fixtures may discharge through the trap or interceptor.
A. 
The Manager or his designee, bearing proper identification, shall be permitted to enter any premises subject to § 174-12 of this article at any reasonable time for the purpose of inspection of facilities and/or records to ensure compliance with the provisions of this article.
B. 
All grease interceptors and/or grease trap systems located on premises subject to § 174-12 of this article shall be inspected at least annually by the Manager or his designee. All such interceptors and/or trap systems located on premises which maintain a dining seating capacity of 50 or more shall be inspected semiannually. A written record of all inspections shall be maintained by the owner.
C. 
All owners or occupiers of premises subject to § 174-12 of this article shall be required to pay the owner a fee for each annual or semiannual inspection conducted pursuant to Subsection B above. The fee shall be established by the owner as reimbursement for costs incurred in conducting the required inspection. The fee shall be included in the owner's next regular billing invoice following the subject inspection.
A. 
The owner is hereby authorized, empowered and directed to make reasonable rules and regulations regarding the grease trap or interceptor requirement and inspection as set forth in §§ 174-12 and 174-13 of this article as it deems necessary, which shall include, but not be limited to:
(1) 
Establishing the appropriate materials, plans and specifications for the type of grease interceptor and/or grease trap system to be installed;
(2) 
Establishing the appropriate materials, plans and specifications for the installation of a grease interceptor and/or grease trap system;
(3) 
Establishing the appropriate inspection and/or testing methods;
(4) 
Establishing the appropriate maintenance activities and schedule required for grease interceptors and/or grease trap systems; and
(5) 
Establishing the appropriate fee for inspection of grease trap interceptors and/or grease trap systems.
B. 
All rules and regulations issued pursuant to this section shall be in writing and shall be approved by the Board of Directors of the owner prior to such rules and regulations becoming effective.