The map entitled "Official Zoning Map of Borough of Waterford" is hereby adopted as part of this chapter. The Official Zoning Map shall be maintained and be available for inspection at the Borough Office. The Official Zoning Map shall be updated in the future should there be any property rezoning amendments made pursuant to the procedure required by this chapter and the Planning Code.[1]
[1]
Editor's Note: See 53 P.S. § 10101 et seq.
The Borough is divided into six districts which are shown by the district boundaries on the Zoning Map, and shall be known as:
R-1
Residential
R-2
Residential
T
Transitional
B-1
Business
B-2
Business
F-P
Floodplain
The boundaries between districts are center lines of streets, or such lines extended or lines parallel or concentric therewith, or property lines when proximate thereto, or may be numerical figures otherwise indicated on the Zoning Map. When the Zoning Officer cannot definitely determine the location of a district boundary, he shall consult the Zoning Hearing Board which shall decide the location of the district boundary.
Any land annexed to or made a part of the Borough subsequent to the adoption of this chapter shall immediately be classified in the same Zoning District as the area to which it is contiguous, as of the effective date of any annexation proceedings. The Planning Commission shall prepare and submit to the Borough Council a report and study of its recommendations for rezoning of the annexed territory. The Planning Commission shall hold at least one public hearing thereon before submitting its final report to the Council.
The minimum lot and yard requirements and other development standards for each zoning district are set forth within the chart located in § 280-19. These standards must be met at the minimum, as well as any other requirement(s) listed within this chapter that apply to the respective use. The permitted uses are set forth within the table located in § 280-18. Any use not expressly listed for a district, or uses which the Zoning Officer cannot interpret as being of the same classification as a listed use, are prohibited within the district. Permitted uses require normal application procedures through the Zoning Officer. The established zoning districts within this chapter are designed to achieve the intent of the Borough Comprehensive Plan Supplement, more specifically the Borough Land Use Plan Map of that plan.
The purpose of this district is to preserve the primary areas of single-family residential dwellings. Additional land uses that are compatible with lower-density single-family detached dwellings are also provided for within this district.
The purpose of this district is to provide for a diverse residential composition through allowing a wide variety of housing types to serve the future housing needs of the Borough. Secondary uses that are comprised of public services or housing that are compatible with higher-density residential uses are also provided for within this district.
The purpose of this district is to provide sufficient land area for the commercial and apartment potential of the Borough primarily through its redevelopment of existing structures and land. While the district is primarily designed for shopping and housing convenience of persons residing within the Borough, the uses provided for also serve regional interests and needs, and is designed and intended to permit a wide range of commercial uses, institutional uses, and non-single-family housing. Standards are developed to provide a functional and efficient shopping and higher-density residential atmosphere; to protect existing investments; and encourage redevelopment and revitalization with adequate off-street parking facilities.
The purpose of this district is to accommodate, to the extent possible, the existing central business district and its unique features of side-by-side, no-frontage and on-street parking layout.
The purpose of this district is to provide sufficient land area for the business needs and potential of the Borough, primarily through the development of open land. This district will contain only those industrial establishments, nonresidential commercial activities, and facilities for manufacturing, processing, packaging, storage and warehousing which can conform to the performance standards of this chapter.
The purpose of this district is to provide for the protection of life and property in the recognized one-hundred-year floodplain of the Borough, which includes Lake LeBoeuf, Trout Run and LeBoeuf Creek, as is identified in the Flood Insurance Rate Maps (FIRM) and related study prepared by the Federal Insurance Administration. The Floodplain District, as mapped specifically (officially) within the aforementioned FIRM Study, shall be considered an area whereby all uses and structures are subject to special development standards. All uses and structures shall be regulated by Chapter 137, Floodplain Management, of the Code of the Borough of Waterford to protect the health, safety and welfare of the Borough's residents and businesses.
The permitted uses for each district, as shown in the following table,[1] shall be according to the common meaning of the term or according to the definitions given in Article VIII. The districts are shown by the symbols as designated in § 280-8.
The following chart delineates the basic development standards for each district. Specific applications and further description of these requirements are included within § 280-20. The letters in parentheses in the chart refer to the respective subsections of § 280-20.
Basic Development Standards
Minimum
Maximum
District
(I)
Lot Area
(A)
(square feet)
Lot
Width
(H)
(feet)
Front
Yard
(B, C, D, E)
(feet)
Side
Yard
(B, D)
(feet)
Rear
Yard
(B, D)
(feet)
Unit Size
(K)
(square feet)
Height
(F)
(feet)
Lot Coverage
(G)
(percent)
R-1 structures
Accessory
30
5
5
25
Include in overall %
Single-family detached
12,500
82.5
30
10
30
1,000
35
35%
All other
12,500
82.5
30
10
30
1,000
35
40%
R-2 structures
Accessory
25
5
5
25
Include in overall %
Single-family detached
7,500
60
25
10
25
800
35
40%
Other residential uses
7,500 + 800 (A)
60
25
10
25
800
40
40%
All other
7,500
60
25
10
25
800
40
45 %
T structures
Accessory
25
5
5
25
Include in overall %
Residential
5,500 + 600 (A)
75
25
10
25
600
45
45%
All other
5,500
75
25
10
25
600
45
50%
B-1 structures
Residential
3,500 + 400 (A)
20
10 (J)
5 (J)
10
400
45
50%
All other
3,500
20
10 (J)
5 (J)
10
400
50
60%
B-2 structures
All uses
20,000
100
50
20
50
400
50
70%
The following requirements apply to the previous § 280-19. The letters in parentheses in § 280-19 refer to the following subsections.
A. 
Minimum lot area shall be exclusive of street rights-of-way or access easements. In the R-2, T, B-1 and B-2 Districts, minimum lot area shall increase the square feet indicated for each dwelling unit or business unit over one.
B. 
Front, side and rear yard requirements are established from the edge of the right-of-way and/or adjacent property line.
C. 
Front yard setbacks in existing developed areas may be reduced by the Zoning Officer in those situations where a continuity of existing setback situations have been established. In such situations, the minimum front yard setback shall be determined by an averaging of the existing buildings within 150 feet of both sides of the proposed structure on the same side of the street.
D. 
Exceptions to yard requirements are granted for the following principal use projections: steps or stoops, eaves, cornices and belt courses, chimneys, and open fire escapes.
E. 
Corner lots shall have one front yard requirement for that portion of the lot, facing a street right-of-way, which is the primary building orientation.
F. 
Measuring of building height shall be established from the average elevation of the finished grade at the front of the structure to the highest point of the structure. When the following conditions are met, height limits may be increased up to a 50% increase over those specified. Building height in excess of the height above ground level allowed in any district may be permitted, provided all minimum front, side and rear yard depths are increased one foot for each additional foot of height. The following structures are exempt from height requirements provided they do not constitute a hazard to an established airport: television and radio towers; church spires; belfries; monuments; tanks; water and fire towers; ornamental towers; elevator bulkheads; chimneys; smokestacks; flagpoles; wind generators; and other necessary mechanical apparatus normally carried above roof level.
G. 
Building coverage is that total coverage by all structures, both principal and accessory uses.
H. 
A portion of all lots must abut a street right-of-way for at least 30 feet. No lot can be landlocked.
I. 
Accessory uses are not permitted within the front yard.
J. 
Permitted uses in the B-1 District may be allowed to reduce or eliminate the setback requirement for one or both front or side yards provided that approval is granted by the Zoning Hearing Board under variance procedure. No side yard, however, shall be permitted closer than 10 feet to any residential district.
K. 
All principal buildings and structures shall have the minimum unit size with the habitable floor area indicated for each dwelling unit or business unit as applicable. In no case shall the habitable floor area be less than 100 square feet per resident and/or employee on maximum shift as applicable. The entire habitable floor area of a principal building or structure shall be placed on a full perimeter permanent foundation consisting of at least an eight-inch-by-eighteen-inch continuous concrete footer, at a depth of 40 inches below finished grade; and a continuous concrete (block or poured) supporting wall up to finished grade, which may include doors, windows and/or utility connections.