A.
Non-food-contact surfaces. Surfaces of equipment not intended for
contact with food, but which are exposed to splash or food debris
or which otherwise require frequent cleaning, shall be:
B.
Fixed equipment spacing or sealing.
(1)
A unit of equipment that is fixed because it is not easily movable
shall be installed so that it is:
C.
Fixed equipment elevation or sealing.
(2)
If no part of the floor under the floor-mounted equipment is more
than 15 centimeters (six inches) from the point of cleaning access,
the clearance space shall be not less than 10 centimeters (four inches).
(3)
This subsection shall not apply to display shelving units, display
refrigeration units, and display freezer units located in the consumer
shopping areas of a retail food store, if the floor under the units
is maintained in a clean condition.
D.
Table-mounted equipment that is not easily movable shall be elevated
on legs that provide at least 10 centimeters (four inches) of clearance
between the table and equipment, except that:
(1)
It shall be acceptable for the clearance space between the table
and table-mounted equipment to be not less than 7.5 centimeters (three
inches) if the horizontal distance of the tabletop under the equipment
is no more than 50 centimeters (20 inches) from the point of access
for cleaning; and
(2)
It shall be acceptable for the clearance space between the table
and table-mounted equipment to be not less than five centimeters (two
inches) if the horizontal distance of the tabletop under the equipment
is no more than 7.5 centimeters (three inches) from the point of access
for cleaning.
E.
Aisles and working spaces.
(1)
Aisles and working spaces between units of equipment and walls shall
be unobstructed and of sufficient width to permit employees to perform
their duties readily without contamination of food or food-contact
surfaces by clothing or personal contact.
(2)
All easily movable storage equipment, including but not limited to
pallets, racks and dollies, shall be positioned to provide accessibility
to working areas.
F.
Removable kick plates. Kick plates shall be designed so that the
areas behind them are accessible for inspection and cleaning.
G.
Vending machines; vending stage closure. The dispensing compartment
of vending machines that serve potentially hazardous food shall be
equipped with a self-closing door or cover if the machines are:
(1)
Located in an area that is outside the confines of a licensed food
establishment or retail food store which otherwise affords protection
against the rain, windblown debris, insects, rodents, and other contaminants
that are present in the environment; or
(2)
Available for self-service during hours when they are not under the
full-time supervision of a food employee.
H.
Vending machines; liquid waste products.
(1)
Vending machines designed to store beverages which are potentially
hazardous food packaged in containers made from paper products shall
be equipped with diversion devices and retention pans or drains for
container leakage.
(2)
Vending machines that dispense liquid potentially hazardous food
in bulk shall be:
I.
Vending machine doors and openings.
(1)
Vending machine doors and access opening covers to food and container
storage spaces shall be tight-fitting so that the space along the
entire interface between the doors or covers and the cabinet of the
machine, if the doors or covers are in a closed position, is no greater
than 1.5 millimeters or 1/16 inch.
(2)
Vending machine service connection openings through an exterior wall
of a machine shall be closed by sealants, clamps, or grommets so that
the openings are no larger than 1.5 millimeters or 1/16 inch.
J.
Drainage of equipment compartments. Equipment compartments that are
subject to conditions inviting accumulation of moisture, including
but not limited to condensation, food or beverage drip, or water from
melting ice, shall be sloped to an outlet that allows complete draining.
K.
Self-draining sinks and drain boards. Sinks and drain boards shall
be self-draining.