B.Â
In new or remodeled food service establishments or retail food stores
at least one utility sink or curbed cleaning facility with a floor
drain shall be provided and shall be the only drain used for:
C.Â
Utility sinks or curbed cleaning facilities shall be installed on
the main food preparation level.
A.Â
All plumbing shall be installed and maintained as follows:
(1)Â
Devices shall be installed to protect against backflow and backsiphonage
at all fixtures and equipment where an air gap at least twice the
diameter of the water supply inlet, but not less than 25 millimeters
(one inch), is not provided between the water supply inlet and the
fixture's flood level rim;
(2)Â
A backsiphonage device shall be installed on all faucets to which
hoses are attached;
B.Â
Use of nonpotable water. Nonpotable water shall be allowed for appropriate
uses, including but not limited to air conditioning and fire protection,
provided that: