A.
Floors and floor coverings in food service establishments and retail
food stores, except for those in dining areas, shall be:
D.
Sawdust, wood shavings, peanut hulls, or similar material shall not
be used as a floor covering.
E.
Floors that are water flushed for cleaning, receive discharges of
water or other fluid waste from equipment, or are located in areas
where pressure spray methods for cleaning equipment are used shall
be:
G.
In all new or remodeled food service establishments or retail food
stores in which cleaning methods other than water flushing are used
for cleaning floors, the floor and wall junctures shall be coved and
closed to no larger than one millimeter (1/32 inch).
I.
Exposed utility service lines and pipes shall be installed so as
not to obstruct or prevent cleaning of the floor.
J.
Exposed horizontal utility service lines and pipes shall not be installed
on the floor of new or remodeled food service establishments and retail
food stores.
K.
Floors, mats, and slatted wooden flooring shall be:
(1)
Kept clean;
(2)
Cleaned with dustless methods of cleaning, including but not limited
to vacuum cleaning, wet cleaning, or the use of dust-arresting compounds
with brooms; and
(3)
Except for emergency cleaning, cleaned during periods when the least
amount of food is exposed, including but not limited to after closing
or between meals.
L.
Notwithstanding the provisions of this section, anti-slip floor covering
shall be allowed in areas where its use is necessary for safety reasons.
B.
The walls, including nonsupporting partitions, wall coverings, and
ceilings, of walk-in refrigerating units, food preparation areas,
equipment washing and utensil washing areas, toilet rooms and vestibules
shall be:
D.
F.
Wall and ceiling covering materials shall be attached and sealed
in a manner which renders them easily cleanable.
G.
Walls, ceilings, attached equipment, and decorative materials shall
be:
H.
In new or remodeled establishments, all construction of walls and
ceilings in the vicinity of high heat and/or steam producing equipment,
including but not limited to grills and hot water sanitizing dishwashers,
shall be constructed of materials resistant to such heat and/or steam.
I.
Concrete or pumice blocks used for interior wall construction in
food preparation areas, equipment and utensil washing areas, toilet
rooms and vestibules shall be finished and sealed to provide a smooth
and easily cleanable surface.
J.
Ventilation hoods and devices shall be designed to prevent grease
or condensation from collecting on walls and ceilings and from dripping
into food or onto food-contact surfaces.
K.
Filters or other grease-extracting equipment shall be installed and
readily removable for cleaning and replacement if not designed to
be cleaned in place.