[Ord. of 10-27-1997(1)]
(a) 
New or replacement fixtures. In all new construction and in all replacement of the below listed fixtures only fixtures not exceeding the following rates and/or water usage shall be installed, provided, however, that exceptions may be permitted if allowed by the Virginia Uniform Statewide Building Code:
Type
Rate/Water Usage
Water closet
1.6 gallons per flushing cycle
Urinal
1.0 gallon per flushing cycle
Shower head
2.5 gallons per minute (gpm) at 80 pounds per square inch (psi)
Lavatory, private
2.5 gpm at 80 psi
Lavatory, public
0.5 gpm at 80 psi
Lavatory, self-closing
0.25 gallon per metering cycle
Sink faucet
2.2 gpm at 60 psi
(b) 
Lavatories for public use. Faucets or lavatories located in restrooms intended for public use shall be of the metering or self-closing type.
(c) 
Car wash installations. All car wash installations shall be equipped with an approved water recycling system.
(d) 
Continuous flow equipment. Any water connected device or appliance requiring a continuous flow of five gallons per minute or more shall be equipped with a water recycling system approved by the Building Official.