[Ord. No. 08-06 §9, 12-30-2008]
A. 
A certain document, three (3) copies of which one (1) copy is on file in the office of the Cass County Clerk and the remaining two (2) copies may be maintained in the Building Codes office of the County of Cass, Missouri, being marked and designated as the International Fire Code, 2006 Edition, including Appendix Chapters B, C, D, E and F, as published by the International Code Council, Inc., be and is herby adopted as the Building Code of the County of Cass in the State of Missouri for the control of building and structures as herein provided; and each and all of the regulations, provisions, penalties, conditions and terms of said Building Code are hereby referred to, adopted and made a part hereof, as if fully set out in this Article, with the additions, insertions, deletions and changes, if any, prescribed in Subsection (B) hereof and Section 500.020 of this Chapter.
B. 
The following Sections are hereby revised:
IFC Section 101.1. Insert: Cass County.
IFC Section 102.6. Reference Codes and Standards. Amend as follows by adding: The ICC Electrical Code referenced in Chapter 45 has been deleted in its entirety and replaced with NFPA70 (National Electrical Code, 2005 Edition). Whenever the term ICC Electrical Code has been used in this code and the referenced standards, the provisions of this Section shall apply.
IFC Section 105.7. Required construction permits. Delete in its entirety Section 105.7 through 105.7.13.
IFC Section 307. Delete in its entirety Section 307. Amend as follows: Shall be as per each fire district.
IFC Section 901.5. Installation acceptance testing. Amend as follows: Fire detection and alarm systems, fire extinguishing systems, fire hydrant systems, fire standpipe systems, fire pumps, private fire mains and all other protection systems and appurtenances thereto shall be subject to acceptance test(s) as contained in the installation standards and as approved by the Building Code Official and Fire Code Official. The Building Code Official and Fire Code Official shall be notified 48 hours before any required acceptance testing is performed. It shall be unlawful to occupy portions of a structure until the required fire protection systems within that portion of the structure have been tested and approved.
IFC Section 903.2.1.2. Group A-2. Amend item number 2 as follows: delete 100 and insert 300.
IFC Section 903.2.7. Group R. Amend as follows: Add Exception: One- and two-family dwellings.
IFC Section 903.3.1.1.1. Exempt locations. Amend item 2 as follows: Add at the end of the paragraph and Building Code Official.
IFC Section 3204.3.1.1. Limits in which the storage of flammable cryogenic fluids in stationary containers is prohibited. Insert: By permit only.