The design standards set forth by these regulations are intended to ensure proper development in the Township.
A. 
The following land subdivision principles, standards, and requirements shall be applied by the Township in evaluating the plans for proposed subdivisions and shall be considered minimum requirements.
B. 
In reviewing subdivision plans, the Township will consider the adequacy of existing or proposed community facilities to serve the proposed development.
C. 
The subdividing of land shall be done in a manner that will not have the effect of denying adjacent property owners access to the streets and ways of the allotment. The Township may require dedicated, improved, or undedicated parcels to be provided for future access to adjacent land.
D. 
Land which is unsuited for development due to hazards such as flooding or the presence of steep slopes shall not be developed (though such land can be included in a subdivision), including:
(1) 
Land subject to flooding or which, if developed, will aggravate flooding conditions upon other lands.
(2) 
Landslide-prone areas. In areas where soils or underlying geology may be unstable, geotechnical investigation may be required. Said geotechnical reports must be completed and signed by a licensed professional engineer.
E. 
Proposed subdivisions and land developments shall be coordinated with existing nearby neighborhoods or developments so that the community, as a whole, may develop harmoniously.
F. 
Proposed land uses and lot sizes shall conform to the Township of Potter Zoning Ordinance.[1]
[1]
Editor's Note: See Ch. 210, Zoning.
A. 
Minimum street right-of-way widths and cartway widths shall be as follows:
Type of Street
Cartway3 With Curbs
(feet)
Cartway2 No Curbs
(feet)
Right-of-Way
(feet)
Shoulders
(feet)
Cul-de-sac1
24*
20
50
4
Minor/local
24*
20
50
4
Collector
36
22
60
8
Industrial/commercial
36
28
60
8
Arterial
As prescribed by the Pennsylvania Department of Transportation's Design Standard
NOTES:
1Residential; other culs-de-sac follow other commercial or industrial standards.
2Requires shoulders.
3Wedge curbs are required; shoulders are not required.
*Two twelve-foot traffic lanes.
To determine the classification of a residential street, the following two tables shall be used as a guide:
Projected Daily Traffic Volume (ADT)*
Street Classification
Volume
Cul-de-sac
0-250
Minor/local
0-1,000
Collector
1,000-3,000*
Source: Table 2-1, Residential Streets, 2nd edition, American Society of Civil Engineers, National Association of Home Builders, Urban Land Institute
Residential Trip Generation Rates Daily Vehicle Trips Per Dwelling Unit*
Type
Weekday
Peak Hour
Single-family detached Apartments
10.0
1.0
All
6.0
0.7
Low-rise
7.0
0.7
High-rise
4.0
0.4
Townhouse and single-family condominiums
6.0
0.6
Source: Table 2-2, Residential Streets, 2nd edition, American Society of Civil Engineers, National Association of Home Builders, Urban Land Institute (figures rounded)
NOTES:
*The Township will accept updated traffic generation data from such sources as the Trip Generation Manual of the Institute of Transportation Engineers.
Note: In the event the projected volume of a street exceeds 3,000 vehicles per day, then its design shall be based upon current PennDOT or other accepted engineering standards but in no event shall be less than the standards for a collector, as shown in § 185-28A.
B. 
In cases where a new subdivision is planned to join the street system on an existing subdivision, the above minimum requirements shall apply except where the existing streets and rights-of-way are larger than required. In this event, the Township may require that the new streets and rights-of-way be as large as those in the existing subdivision. Any street that is planned, though not already established, shall be continued at not less than its width as planned.
C. 
Provisions for additional street width (right-of-way) may be required by the Township in specific cases for:
(1) 
Public safety and convenience.
(2) 
Parking in commercial and industrial areas and in areas of high-density residential development.
D. 
General design criteria for streets not otherwise covered in this chapter shall be in accordance with specifications as set forth by the Township and appropriate publications of the Pennsylvania Department of Transportation.
E. 
Culs-de-sac.
(1) 
In no event shall a street be allowed to dead end without a permanent cul-de-sac.
(2) 
Residential dead-end streets (culs-de-sac) may be permitted when it is clear that through traffic is not essential. A dead-end street must have adequate turning space for vehicles, which shall include a minimum right-of-way radius of 50 feet and a minimum road edge (excluding shoulders) or curb radius of 40 feet. The entire turnaround area is to be paved. Full pavement shall extend to the outer edge of the forty-foot radius. In no event shall the shoulder area be considered as part of the required minimum road width. Culs-de-sac shall be signed with a "No Outlet" sign for ingress traffic and a "Stop" sign for egress traffic. In no event shall a cul-de-sac serve more than 100 dwelling units.
(3) 
Culs-de-sac for commercial or industrial developments shall be designed to allow for the turn of a full-sized tractor-trailer combination as allowed by the Commonwealth of Pennsylvania.
F. 
Street intersections shall comply with the following requirements:
(1) 
Radii.
(a) 
All curbs or pavement outer edges at intersections shall be rounded by a minimum radius of:
[1] 
Collector, commercial, and arterial streets: 40 feet.
[2] 
Minor and local streets: 25 feet.
[3] 
Industrial streets: 50 feet.
(b) 
Thirty-foot radii shall be used where minor streets intersect collector and/or arterial streets.
(2) 
Sight triangle.
(a) 
When visual obstructions on any lot corner within the development would create a traffic hazard by limiting clear vision across a corner lot from a height of three feet above the finished paved area, at the center line of the right-of-way, such structure and/or vegetation shall be removed in conjunction with grading the right-of-way to provide a minimum sight line in a clear sight triangle:
[1] 
Seventy-five feet from the point of intersection of the center lines of two streets where both are minor streets.
[2] 
One hundred feet from the point of intersection of the center lines of two streets where one is a collector street.
[3] 
One hundred fifty feet from the point of intersection of the center lines of two streets where one is an arterial street.
(b) 
When an arterial, commercial, industrial or collector and a minor street intersect, each shall retain its respective footage requirements along the center line to form the sight triangle. No building or structure shall be permitted in this sight triangle. Sight triangles shall be shown on the plan. (See also the Public and Private Improvements Code.)
(3) 
Where the grade of any street at the approach to an intersection exceeds 4%, a leveling area shall be provided, with a transitional grade not to exceed 3% for a minimum distance of 50 feet from the nearest right-of-way line of the intersection.
(4) 
Intersections of more than two streets shall not be allowed.
(5) 
Minimum street intersection angles shall be 75°. Right-angle intersections shall be used whenever possible.
(6) 
Intersecting streets shall be separated by 200 feet or more, measured between center lines along the center line of the intersected street.
G. 
Horizontal curves shall be laid on all deflecting angles along the center line of streets, and the degree of curvature shall be set to assure the proper sight distance, as required by Table A below.
H. 
Vertical curves shall be used in changes of grade exceeding 1% and shall be designed for maximum visibility as set forth by Table A below.
I. 
In general, minor and collector streets shall not join into the same side of arterial streets at intervals of less than 800 feet.
J. 
Half streets shall be prohibited.
K. 
Provisions for the extension and continuation of major streets into and from adjoining areas are required. Where a subdivision abuts or contains an existing or proposed collector street, the Township may require reverse-frontage lots or such treatments as will provide protection for abutting properties, reduction in the number of intersections with the major traffic streets, and separation of local and through traffic.
L. 
When the subdivision adjoins unsubdivided acreage, new streets or reserved rights-of-way may be provided through to the boundary lines of the development.
M. 
If the lots in a development are large enough for resubdivision, or if a portion of the tract is not subdivided, suitable access and street openings for such resubdivision shall be provided.
Note: This will not apply if subject land is to be held as permanent dedicated open space. Such access or openings shall not be less than 50 feet in width.
Table A
Design Criteria for Streets1
(Not to Include Intersections)
Type of Street
Item
Comm./Ind.
Collector
Minor/Local
Cul-De-Sac4
Maximum grade2
6.0%
6.0%
12.0%
10.0%
Minimum grade
1.0%
1.0%
1.0%
1.0%
Minimum center-line radius
500 feet
500 feet
250 feet
250 feet
Minimum sight distance3
300 feet
300 feet
250 feet
250 feet
Tangent between curves
150 feet
150 feet
100 feet
100 feet
NOTES:
1For arterial roads, PennDOT standards will apply.
2Grades in excess of the allowable percentage may be approved by the Township where it is clear that it is necessary and that no traffic hazard is or will be created thereby.
3Sight distance shall be measured along the center line of the street between points where a driver's eyes at three feet six inches in height can see an object six inches high. Values shown are minimums. Greater values may be required depending on site-specific criteria.
4Please see cul-de-sac definition; a cul-de-sac is the entire street, not merely the vehicular turnaround.
N. 
All required traffic control devices, including required signs, shall comply with and be installed in accordance with the current Commonwealth of Pennsylvania Department of Transportation, Title 67, Chapter 212 (or as it may be amended). Generally, it shall be the developer's responsibility to perform all required traffic and engineering studies in accordance with PennDOT standards.
O. 
Private streets may be authorized to permit limited subdivision of lots, subject to the following requirements:
(1) 
A maximum of three lots, plus a residual parcel containing one existing residential structure, may be approved for access on a private street.
(2) 
The private street right-of-way shall be a minimum of 50 feet, except as otherwise indicated.
(3) 
The street shall be installed to provide the required minimum width with a mud-free cartway in accordance with the design standards in Subsection O(5) below, which is adequate to enable all-weather passage of vehicles.
(4) 
Sales agreements for all lots abutting the private road shall include notification to purchasers of the nonliability of the Township for road maintenance or related improvements. In addition, a certificate of the nonliability of the Township shall be inscribed on the plan when submitted for municipal approvals.
(5) 
The Township's Public and Private Improvements Code shall detail the construction of these private roads. At a minimum, such roads shall:
(a) 
Have a minimum cartway width of 20 feet.
(b) 
The road bed shall be composed of four inches of rolled and compacted crushed aggregate.
(c) 
Have no grade in excess of 12%.
(d) 
The required cul-de-sac road bed area shall be also composed of four inches of rolled and compacted crushed aggregate.
(e) 
The right-of-way/cartway for private roads shall not be resubdivided or diminished in any way.
(6) 
A temporary turnaround for maintenance and emergency vehicles shall be provided where future street or roadway extensions are designed to occur; said turnaround shall have a minimum sixty-foot diameter curb to curb and be composed of four inches of rolled and compacted crushed aggregate.
(7) 
A private maintenance agreement signed by the developer binding all successors and assigns shall be filed with the Township prior to the approval of the subdivision.
A. 
Curbs. When curbs are installed, the following criteria are to be followed:
(1) 
Wedge curbs will be used.
(2) 
Where sidewalks are installed, curbs shall be depressed at intersections to sufficient width to accommodate wheelchairs. Depression shall be in line with sidewalks where provided. (Note: Appropriate federal ADA standards must be followed.)
(3) 
All curbs and curb cuts shall be constructed in accordance with the Township's Public and Private Improvements Code.
B. 
Sidewalks. Sidewalks may be provided for all major subdivisions where the average lot width is 75 feet or less and for any minor subdivisions where sidewalks exist on abutting parcel(s). The width, depth, design and specifications for sidewalks shall comply with the current sidewalk standards of the Township, but in no event shall sidewalks be less than five feet wide.
A. 
Blocks shall be designed to ensure proper firesafety.
B. 
In general, all blocks in a subdivision shall have a maximum length of 1,600 feet. Blocks subdivided into lots shall be approximately two lot depths in width, except lots along a major thoroughfare which may front on an interior street. Block lengths shall not be less than 600 feet.
C. 
In commercial areas, the block layout shall conform with due consideration to site conditions, to the best possible layout to serve the public, to permit good traffic circulation and the parking of cars, to make delivery and pickup efficient, and to reinforce the best design of the units in the commercial areas.
D. 
The block layout in industrial areas shall be governed by the most-efficient arrangement of space for present use and future expansion, with due regard for worker and customer access parking. Of special interest will be the accommodation of truck traffic.
A. 
Double-frontage and reverse-frontage lots should be avoided except where essential to provide separation of residential development from traffic arterials or to overcome specific disadvantages of topography and orientation. A planting screen easement, across which there shall be no right of access, may be required by the Township along the line of lots abutting such a traffic artery or other disadvantageous use.
B. 
Side lines of lots, so far as practical, shall be at right angles or radial to street lines.
C. 
Lots abutting local streets shall front upon the streets which parallel the long dimension of the block, if possible.
D. 
All lots shall abut by their frontage on a publicly dedicated or approved private street (see also the Township Zoning Ordinance).
A. 
Blocks and lots shall be graded to provide proper drainage away from buildings and to prevent the collection of stormwater in pools.
B. 
Where drainage swales are used to deliver surface waters away from buildings, their grade shall not be less than 1% nor more than 4%. The swales shall be sodded, planted or lined as required. A grading and drainage plan shall be required for all subdivisions and land developments, except minor subdivisions.
C. 
No final grading, fill, or cut shall be permitted with a cut face steeper in slope than two horizontal to one vertical, except under one or more of the following conditions:
(1) 
The material in which the excavation is made is sufficiently stable to sustain a slope of steeper than two horizontal to one vertical, and a written statement of a geotechnical engineer, who is qualified to prepare a geotechnical report, licensed by the Commonwealth of Pennsylvania and experienced in erosion control, to that effect is submitted to the Township Engineer and approved by same. The statement shall state that the site has been inspected and that the deviation from the slope specified hereinbefore will not result in injury to persons or damage to property.
(2) 
A retaining wall designed, certified, and sealed by a licensed professional engineer for which plans have been submitted and approved by the Township Engineer and written approval is provided.
D. 
The top or bottom edge of cut or fill slopes shall be a minimum of 10 feet from property or right-of-way lines of streets or alleys in order to permit the normal rounding of the edge without encroaching on the abutting property. All property lines, or right-of-way lines, where walls or slopes are steeper than one horizontal to one vertical and five feet or more in height shall be protected by a protective fence no less than three feet in height approved by the Township Engineer.
E. 
Where applicable, the provisions of the Township Public and Private Improvements Code, Article V, shall be followed.
A. 
Where a subdivision is traversed by a watercourse, drainageway, channel, or stream, a drainage easement may be required that conforms substantially with the water line of such watercourse, drainageway, channel, or stream and of such width as will be adequate to preserve the unimpeded flow of natural drainage, or for the purpose of widening, deepening, relocating, improving or protecting such drainage facilities.
B. 
Where desirable or necessary, adequate easements or dedications for public service utilities shall be provided for sewer, water, electric power, gas lines, storm drainage and similar services; and no structure or obstruction of any kind shall be placed or allowed to be placed where it will interfere in any way with such easements.
C. 
Utility and drainage easements, where required, shall have a minimum width of 20 feet and be placed at the side or rear of lots whenever possible.
The developer shall work with the Postmaster and/or Fire Marshal in assigning street names to avoid confusing or duplicated street names.
All new roads shall provide storm drainage facilities in accordance with specifications as set forth by the Township Engineer, Potter Township and/or applicable state or federal law or regulation. All subdivisions shall provide a stormwater drainage and management plan.
Gas, electric, water, telephone, and cable utilities shall be located underground in major subdivisions in accordance with utility company standards and in accordance with all other requirements of the Township (see also § 185-48).
A. 
All developers are required to follow the Township or the commonwealth floodplain regulations. In addition, when any floodplains are located within a proposed development, they should be clearly identified on the preliminary and final plat .The developer will use the most-recent floodplain information for the Township, as available from the Federal Emergency Management Agency.
B. 
Any public facilities or utilities which are constructed in a floodplain area shall be designed in accordance with approved regulations. These regulations are set forth in the Township's Floodplain Regulations.[1]
[1]
Editor's Note: See Ch. 112, Floodplain Management.
Sanitary sewer systems shall follow the design and construction criteria as set forth by the Pennsylvania Department of Environmental Protection and the Township, or appropriate authority. All designs must demonstrate compliance with DEP permit requirements and secure DEP approval.
Water systems shall follow the design and construction criteria as set forth by the Pennsylvania Department of Environmental Protection and the Township or appropriate authority and secure all needed approvals. All designs must demonstrate compliance with DEP and agency requirements and/or permit standards.
If required by the Board of Township Supervisors:
A. 
Any trees used as street trees shall be suited for the use intended and the Potter Township area. The Township shall use standard references such as "Street Trees: A Manual for Municipalities" (Richard D. Schein, 1993; Tree Works) to review tree planting proposals. Street tree calipers shall be at least 1 1/2 inches. All landscaping shall be guaranteed for at least one year, and any landscaping found dead or diseased in that one-year period shall be replaced by the developer.