1.Â
For the purposes
of this chapter, the following abbreviations shall have the following
meanings:
sq. ft.
ft.
%
NA
|
=
=
=
=
|
square feet.
linear feet.
percent.
Not applicable.
|
1.Â
Lot area. Any
lot, together with the required yards and open areas on it, shall
be equal to or exceed the minimum lot area established for the zoning
district in which it is located. In case of a subdivision or combination
of lots, no lot shall be created which does not meet the requirements
of this chapter.
2.Â
Required lot
area. Any portion of a lot once designated as a yard or as lot area
per dwelling unit in compliance with the lot area requirements of
this chapter shall not be counted again as a required yard or lot
area per dwelling unit for another lot or building, nor shall it be
sold as a separate lot. Any portion of a lot which is recorded or
otherwise reserved for future streets shall not be used as a factor
in determining lot area per dwelling unit or yard dimensions.
3.Â
Building on nonconforming lots of record. Any nonconforming lot of record, as defined by this chapter, may be used for the erection of a structure conforming to the use of the district in which it is located, subject to the provisions of § 27-1308 of this chapter.
4.Â
Front yards on
corner lots. Lots which abut more than one street shall provide the
required front yards along every street. There shall be no rear yard
required on corner lots, and the remaining yards shall be side yards.
5.Â
Where dwellings
exist on adjacent nonconforming lots which have front, side or rear
yards less than the minimum depth required by this chapter, the minimum
yards required for construction of a dwelling on an adjacent undeveloped
nonconforming lot shall be the average of the front, side or rear
yards of the immediately adjacent developed lots on either side of
the undeveloped lot, provided that in no instance shall a front or
rear yard be less than five feet, and a side yard shall not be less
than 2Â 1/2 feet.
6.Â
Projections into
required front and rear yards. All structures, whether open or enclosed,
including porches, balconies or other platforms above normal grade
level, shall not project into any minimum front, side or rear yard
with the following exceptions:
A.Â
Typical architectural
features, including, but not limited to, bay windows, window sills,
eaves, buttresses, chimneys, cornices, piers or pilasters which do
not project more than 18 inches from the wall of a building may project
into a required front or rear yard.
B.Â
Balconies or
other aboveground platforms, open fire escapes and access steps to
a structure, not exceeding six feet in width, may extend up to three
feet into a required front or rear yard.
C.Â
An unenclosed
porch for a residential structure may extend into a required side
yard, provided that the porch is not more than 10 feet in height and
is no closer than 2Â 1/2 feet to any side lot line or 10 feet
to any rear lot line.
7.Â
Access to public
street. All lots shall have access either directly or via a driveway
to a public street. Such driveway shall have a uniform width of not
less than 12 feet.
8.Â
Height exceptions.
Church spires and towers, chimneys, elevator bulkheads and other mechanical
equipment which is part of the principal structure, standpipes, elevated
water tanks, flagpoles, silos, conveyors and similar structures which
are not intended for human habitation and which are not conditional
uses regulated by Part 11 may exceed the height limitations of the
zoning district in which they are located by not more than 15 feet.
1.Â
Area and dimensional
requirements.
Residential
| |||||
---|---|---|---|---|---|
Single-
Family
|
Two-
Family
|
Group Residence
|
All Other
Principal Uses
| ||
Minimum lot area
|
4,400 sq. ft.
|
8,500 sq. ft.
|
4,400 sq. ft.
|
21,780 sq. ft.
| |
Minimum yard area
| |||||
Front
|
20 ft.
|
20 ft.
| |||
Side
|
Two side yards total 25% of lot width, neither
being less than 5 ft.
|
Two side yards total 25% of lot width, neither
being less than 5 ft.
| |||
Rear
|
25 ft.
|
25 ft. (NOTE: See § 27-402.6 for yard
exceptions.)
| |||
Minimum lot width
|
50 ft.
|
60 ft.
| |||
Maximum lot coverage
|
50%
| ||||
Maximum dwelling unit density
|
10 units per acre
|
N/A
| |||
Maximum height
| |||||
Principal structure
|
36 ft. and three stories
| ||||
Accessory structure
|
See § 27-503
|
1.Â
Area and dimensional
requirements.
Residential
| |||||||
---|---|---|---|---|---|---|---|
Single-Family
|
Two-Family
|
Triplex, Quadruplex
|
Townhouse See also § 27-412
|
Group Residence
|
All Other Principal Uses
| ||
Minimum lot area
|
4,000 sq. ft.
|
8,000 sq. ft.
|
10,000 sq. ft.
|
21,780 sq. ft.
|
4,000
|
10,000 sq. ft. unless specified by this chapter
| |
Minimum yard area
| |||||||
Front
|
20 ft.
| ||||||
Side
|
Two side yards total 25% of lot width, neither
being less than 5 ft.
| ||||||
Rear
|
25 ft. (NOTE: See § 27-402.6 for yard
exceptions.)
| ||||||
Minimum lot width
|
50 ft.
|
110 ft.
|
60 ft.
| ||||
Maximum lot coverage
|
60%
| ||||||
Maximum dwelling unit density
|
15 units per acre
|
N/A
| |||||
Maximum height
| |||||||
Principal structure
|
36 ft. and three stories
| ||||||
Accessory structure
|
See § 27-503
|
1.Â
Area and dimensional
requirements.
Single-
Family
|
Two-
Family
|
Triplexes and Quadruplexes
|
Townhouse See also § 27-502
|
Garden Apartments
| |||
---|---|---|---|---|---|---|---|
Minimum lot area
|
4,000 sq. ft.
|
8,000 sq. ft.
|
10,000 sq. ft.
|
21,780 sq. ft.
|
See § 27-502
| ||
Minimum yard requirements
| |||||||
Front
|
20 ft.
| ||||||
Side
|
Two side yards total 25% of lot width, neither
being less than 5 ft.
|
10 ft.
| |||||
Rear
|
25 ft. (NOTE: See § 27-402.6 for yard
exceptions).
| ||||||
Minimum lot width
|
50 ft.
|
110 ft.
| |||||
Maximum lot coverage
|
65%
| ||||||
Maximum dwelling unit density
|
20 units per acre
| ||||||
Maximum height
| |||||||
Principal
structure
|
Mid-rise: 60 ft. and five stories
All other: 36 ft. and three stories
| ||||||
Accessory structure
|
See § 27-503
|
1.Â
Area and dimensional
requirements.
All Uses
| ||
---|---|---|
Minimum lot area
|
None required
| |
Minimum yard requirements
| ||
Front
|
None required
| |
Side
|
If abutting residential district, 10 ft.; otherwise
none required
| |
Rear
|
20 ft.
| |
Minimum lot width
|
None required
| |
Maximum lot coverage
|
90%
| |
Maximum height
| ||
Principal structure
|
45 ft. and four stories
| |
Accessory structure
|
See § 27-503
|
4.Â
Additional standards.
A.Â
All operations,
activities and storage shall be conducted wholly inside a building
or buildings.
1.Â
Area and dimensional
requirements.
All Uses
| ||
---|---|---|
Minimum lot area
|
3,300 sq. ft.
| |
Minimum yard requirements
| ||
Front
|
No minimum
| |
Side
|
No minimum
| |
Rear
|
20 ft.
| |
Maximum floor area ratio*
|
2:1
| |
Maximum lot coverage
|
90%
| |
Maximum height
| ||
Principal structure
|
45 ft. and three stories
| |
Accessory structure
|
see § 27-503
|
*Note: A 30 ft. by 110 ft. lot with a 20 ft.
rear yard setback at a 2:1 FAR with a 90% impervious surface (lot
coverage ratio) yields a maximum gross floor area of 6,600 sq. ft.
The maximum building footprint this yields is 2,700 sq. ft. In order
to maximize the allowable gross floor area, (6,600 sq. ft.), the building
will be 2.5 stories.
|
4.Â
Additional standards.
The following standards shall apply to all developments within the
C-2 District, unless otherwise excluded by this chapter. Owners of
existing buildings within the C-2 District shall make every effort
feasible to conform with the standards outlined below:
A.Â
Building frontage:
All new construction in the C-2 District shall maintain a sixty-five-percent
building frontage along the established build-to line, (the front
line established by adjacent buildings in the district, or front property
line in the case of zero setback).
B.Â
Ground floor
transparency: The street level facade shall be transparent between
the height of three feet and eight feet above the walkway grade for
no less than 60% of the horizontal length of the building facade.
C.Â
Doorway and
entrances. All primary structures in the C-2 District shall provide
a prominent and highly visible street level doorway or entrance on
all facades of the building which front on a street.
D.Â
Parking areas.
In addition to the parking regulations found in Part 10, the following
standards shall apply to all off-street parking areas within the C-2
District:
(1)Â
No parking
spaces shall be located between the front building facade and the
front building line. No corner lot shall be used as off-street parking
unless the parking area serves as a shared parking area or is an approved
public parking facility.
(2)Â
Off-street
parking spaces may be located on the side of buildings, provided that
the facade of the building facing the parking area is transparent
between the height of three feet and eight feet above the parking
area surface for no less than 30% of the horizontal length of the
building.
1.Â
Area and dimensional
requirements.
Shopping Center
|
All Other Uses
|
Garden Apartments, Mid-rise Apartments,
High-rise Apartments
| ||
---|---|---|---|---|
Minimum lot area
|
2 acres
|
6,000 sq. ft.
|
See § 27-502
| |
Minimum yard requirements
| ||||
Front
|
10 ft.
| |||
Side
|
10 ft., plus one foot for each foot over 35
ft. in height
| |||
Rear
|
30 ft.
| |||
50 ft.
| ||||
Maximum lot coverage
|
75%
| |||
Maximum height
| ||||
Principal structure
|
60 ft. and five stories
| |||
Accessory structure
|
See § 27-503
|
4.Â
Additional standards.
A.Â
All operations,
activities and storage shall be conducted wholly inside a building
or buildings, unless otherwise authorized by conditional use or use
by special exception provisions.
B.Â
All premises
shall be furnished with all-weather, hard surface walks, driveways,
parking and loading areas.
C.Â
Portions of
the property not covered with buildings, roads, walkways, active or
passive recreational areas, parking and loading areas or similar uses
shall be planted and suitably landscaped.
[1]
Editor's Note: Original § 260-25, WDD Waterfront
Development District community development objectives, was repealed
9-13-2018 by Ord. No. 2018-06.
[1]
Editor's Note: Original § 260-26, WDD Waterfront
Development District community development requirements, was repealed
9-13-2018 by Ord. No. 2018-06.
[1]
Editor's Note: Original § 260-27, WDD Waterfront
Development District site development standards, was repealed 9-13-2018
by Ord. No. 2018-06.
1.Â
Area and dimensional
requirements.
All Uses
| ||
---|---|---|
Minimum lot area
|
5,000 ft.
| |
Minimum yard area
| ||
Front
|
20 ft.
| |
Side and rear
|
To maximize the potential for design promoting
open space, zero lot lines are permissible, except that at one side
setback equals 15 ft. to provide access for emergency safety equipment
and personnel and the distance between buildings is 20 ft.
| |
Minimum lot width
|
35 ft.
| |
Maximum lot coverage
| ||
New development
|
50%
| |
Redevelopment of existing uses
|
To be reviewed on a case-by-case basis
| |
Maximum height
| ||
Principal structure
|
35 feet and three stories
| |
Accessory structure
|
See § 27-503
|