Wastes from the following shall not discharge directly into any building drain, soil or waste pipes: a refrigerator, icebox, soda fountain, bar waste, fish or meat counters or other receptacle, appliance, device or apparatus which is used for storage, preparation or processing of food or drink and which is not water-connected; an appliance, device or apparatus using water as a cooling or heating medium; a water still; a swimming pool; a water treatment device or a water-operated device.
Drinking fountains may be installed with indirect wastes or shall be connected directly into a drainage system trapped and vented same as other fixtures. Such pipe shall have a minimum diameter of 1 1/4 inches.
Fixtures connected to indirect wastes shall be trapped, but it shall be unnecessary to vent such fixture. The piping shall be installed with cleanouts on horizontal runs.
Indirect waste pipes shall be installed in accordance with the provisions of the other sections of this chapter applicable to sanitary drainage piping.
The diameter of refrigerator waste pipes shall not be less than 1 1/2 inches in diameter. Such pipes shall be of brass, copper or galvanized wrought iron.
Indirect waste pipes shall discharge into a water-supplied, trapped and vented open sink or other approved receptacle which shall be located in an accessible, ventilated place. The air gap shall be equal to or greater than the nominal diameter of the waste pipe.
Water lifts, expansion tanks, cooling jackets, sprinkler systems, drips or overflow pans, or similar devices which waste clear water only, may discharge onto a roof, into a sump or so as to drain into a trapped fixture.
Indirect waste pipes receiving the discharge from drinking fountains or refrigerators on three or more floors shall be vented through the roof.
No toxic, corrosive, inflammable, explosive or other liquid, vapor, gas or substance of any kind harmful to the drainage system shall be discharged into such drain or sewer unless subjected to treatment approved by the administrative authority.
Acid or alkaline wastes harmful to the normal drainage piping materials shall be neutralized or otherwise rendered harmless before discharge to the drainage system.
Appliances, devices or apparatus not regularly classed as plumbing fixtures, but which have drips or drainage outlets, shall be drained by special waste pipes discharging into an open fixture or other approved receptacle.