[HISTORY: Adopted by the Commissioner of Public Works of the City of Hudson 3-17-1970 (Ch. A123 of the 1973 Code). Amendments noted where applicable.]
GENERAL REFERENCES
Gasoline stations — See Ch. 161.
Streets and sidewalks — See Ch. 266.
Depressed curb driveways — See Ch. A331.
Finished
Curbs
Sidewalks
Size
6 inches x 18 inches x 5 feet
4 inches x 5 feet
Finish
 —  
Broom 
Edging
1/2-inch radius
1/2-inch radius
Mix
1:1 1/2:3 with air entrainment
1:1 1/2:3 with air entrainment
Pitch
 — 
 1/4-inch on 1 inch
Grade and alignment
Established by the Department of Public Works 
Expansion
1/2-inch premolded joint every 50 feet and between curb and pavement
12-inch premolded joint every 50 feet and between walk foundation
Construction method
5-foot sections — removable metal plates
Alternate block
Foundations*
2 inches No. 2 stone — 3-inch porous tile to grade. Cover joints with burlap, place 4 inches of screened gravel or broken stone above tile
3 inches of gravel
Driveways
Special depressed curb and ramp requirements [1]
*Requirement determined by Department of Public Works.
Note: Leave three-inch clearance around hydrants.
[1]
Editor's Note: See Ch. A331, Depressed Curb Driveways.