A. 
All fuel oil tanks shall be placed at the rear of mobile homes and not located less than five feet from any exit.
B. 
Individual fuel tanks will be buried or acceptably concealed.
C. 
A central storage tank is recommended, acceptably concealed.
D. 
Supports or standards for fuel storage tanks are to be of a noncombustible material.
A. 
Natural gas piping systems shall be installed and maintained in conformity with accepted engineering practices.
B. 
Each mobile home lot provided with piped natural gas shall have an approved shutoff valve and cap to prevent accidental discharge of gas.
A. 
Such system shall be provided with safety devices to relieve excessive pressures and shall be arranged so that discharge terminates at a safe location.
B. 
Systems shall have at least one accessible means for shutting off gas. This means shall be located outside of individual mobile homes.
C. 
All liquid propane gas piping shall be well supported and protected against mechanical injury.
D. 
Storage tanks shall not be less than 100 pounds and must be located at the rear of the mobile home and no closer than five feet from any exit and acceptably concealed.
E. 
A central storage tank is recommended, to be acceptably concealed.