[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
The purpose of this Article of the City Code is to promote the use of renewable energy and to provide for the development, installation, and construction of renewable energy systems on residential property subject to criteria and regulations established to protect the public health, safety and welfare of the residents of the City.
[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
For the purposes of this Article, terms used for renewable energy structures shall be defined as follows:
BUILDING-INTEGRATED PHOTOVOLTAIC SYSTEM (BIPV)
An active solar system that is an integral part of a principal or accessory building, rather than a separate mechanical device, replacing or substituting for an architectural or structural component of the building. Building-integrated systems include but are not limited to photovoltaic or hot-water solar systems that are contained within roofing materials, windows, skylights, and awnings. PV shingles or tiles, PV laminates, and PV glazing are all examples of BIPV.
GLARE
The effect produced by light reflecting from a solar energy system with an intensity sufficient to cause annoyance, discomfort, or loss in visual performance and visibility.
GROUND SOURCE HEAT PUMP SYSTEM
A system that uses the relatively constant temperature of the earth to provide heating in the winter and cooling in the summer.
GROUND SOURCE HEAT PUMP SYSTEM, CLOSED LOOP
A system that circulates a heat transfer fluid, typically food-grade antifreeze, through pipes or coils buried beneath the land surface.
GROUND SOURCE HEAT PUMP SYSTEM, HORIZONTAL
A closed loop ground source heat pump system where the loops or coils are installed horizontally in a trench or series of trenches no more than twenty (20) feet below the surface.
GROUND SOURCE HEAT PUMP SYSTEM, OPEN LOOP
A system that uses groundwater as a heat transfer fluid by drawing ground water from a well to a heat pump and then discharging the water over land, directly in a water body or into an injection well.
GROUND SOURCE HEAT PUMP SYSTEM, VERTICAL
A closed loop ground system heat pump where the loops or coils are installed vertically in one (1) or more borings below the land surface.
GROUND-MOUNTED SOLAR ENERGY SYSTEM
A solar energy system that is not attached to a structure and is affixed to the ground.
PHOTOVOLTAIC (PV) SYSTEM
A solar energy system that converts sunlight into electrical energy.
ROOF-MOUNTED SOLAR ENERGY SYSTEM
A solar energy system affixed to the roof of either a principal or accessory structure.
SMALL WIND ENERGY SYSTEM
A structure designed for the purpose of converting wind energy into electrical energy to reduce on-site consumption of utility power.
SOLAR ENERGY SYSTEM
A structure designed for the purpose of collecting and transforming solar energy into thermal or electrical energy. Solar energy systems may include photovoltaic or solar thermal systems.
SOLAR THERMAL SYSTEM
A solar energy system that uses sunlight to produce heat that is used for space heating and cooling, domestic hot water, and heating pool water.
[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
A. 
Solar and small wind energy systems are structures which shall be permitted on all residential property zoned residential, estate or non-urban district.
B. 
The requirements of the City Code shall apply to all solar and small wind energy systems installed or modified after the effective date of this Article on all residential property zoned residential, estate or non-urban district.
C. 
Any upgrade, modification, or structural change that alters the size or placement of an existing solar or small wind energy system shall comply with the provisions of this Article.
[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
A. 
The following general requirements apply to all solar energy systems. All solar energy systems shall:
1. 
Comply with all minimum yard structure setback requirements for the zoning district in which the property is located;
2. 
Be placed in such a manner that glare will not be directed onto nearby properties or adjacent streets; and
3. 
Adhere to Chapter 500 of the City Code pertaining to minimum standards for property maintenance.
B. 
Minimum Requirements For Ground-Mounted Solar Energy Systems. All ground-mounted solar energy systems shall:
1. 
Be located in the rear yard of the residential property;
2. 
Not exceed ten (10) feet in height as measured from the average grade at the base of the structure to the highest point of the structure;
3. 
Have all exterior electrical and/or plumbing lines connecting to a principal or accessory structure be located underground; and
4. 
Ground-mounted solar energy systems must be substantially screened from public view (including adjacent properties and public rights-of-way) by fencing, walls, plantings or other architectural feature or any combination thereof; provided, however, that screening shall not be required to be so dense, so tall or so located as to render the equipment essentially non-functional.
C. 
Minimum Requirements For Roof-Mounted Solar Energy Systems.
1. 
All roof-mounted solar energy systems shall be mounted on a principal or accessory building or structure.
2. 
Mounting on sloped roofs:
a. 
System shall not exceed the height of the existing roofline as illustrated below.
b. 
System shall be mounted parallel to the roof, not to exceed twelve (12) inches above the roofline to which it is affixed.
c. 
System shall be positioned in a symmetrical fashion and centered on the plane of the roof on which it is located.
d. 
System shall be set back at least two (2) feet from any outside edge, ridge, or valley of the roof.
500 Mounting on Sloped Roofs.tif
3. 
Mounting On Flat Roofs.
a. 
System shall be mounted parallel to the roof, not to exceed thirty-six (36) inches above the roofline to which it is affixed.
b. 
System shall be positioned in a symmetrical fashion and centered on the plane of the roof on which it is located.
c. 
System shall be set back at least two (2) feet from any outside edge, ridge, or valley of the roof.
D. 
Building-Integrated Photovoltaic Systems.
1. 
Building-integrated photovoltaic systems may be located on any roof plane or wall.
[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
A. 
One small wind energy system shall be permitted per residential lot and shall:
1. 
Comply with all minimum yard structure setback requirements for the zoning district in which the property is located;
2. 
Only be located in the rear yard of the residential property;
3. 
Be ground mounted only;
4. 
Have a maximum tower height that does not exceed the maximum height permitted for a structure in the zoning district in which the tower is located or the maximum height of the existing residential structure, whichever is less;
5. 
Height shall be measured as the distance from average grade at the base of the structure to the highest point of the structure;
6. 
Adhere to Chapter 500 of the Chesterfield City Code pertaining to minimum standards for property maintenance;
7. 
Be placed in such a manner that glare will not be directed onto nearby properties or adjacent street and does not create significant shadow flicker impacts. "Significant shadow flicker" is defined as more than thirty (30) hours per calendar year on abutting occupied buildings;
8. 
Have a sound level that does not exceed sixty (60) decibels as measured at the site property line, except during short-term events such as severe wind storms and utility outages;
9. 
Either be stock color from the manufacturer or painted with a non-reflective, unobtrusive color that blends in with the surrounding environment;
10. 
Have all exterior electrical lines located underground; and
11. 
Not be illuminated by artificial means, except where the illumination is specifically required by the Federal Aviation Administration or other Federal, State, or local regulations.
[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
A. 
Only closed loop ground source heat pump systems utilizing heat transfer fluids as defined are permitted. Open loop ground source heat pump systems are prohibited.
B. 
Setbacks.
1. 
All components of ground source heat pump systems including pumps, borings and loops shall be set back at least five (5) feet from all property lines.
2. 
Aboveground equipment associated with ground source heat pumps shall not be installed in a front yard. Equipment shall be located in the side or rear yard, set back at least five (5) feet from the property line.
3. 
Ground source heat pump systems shall not be located or encroach upon any recorded easement.
[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
A. 
Municipal zoning approval is required for all solar, small wind energy systems and ground source heat pump systems prior to the issuance of a building permit. The following information shall be submitted to the Department of Planning:
1. 
An application for municipal zoning approval.
2. 
Five (5) copies of a plot plan, drawn to scale and including the following information:
a. 
Location and size of the renewable energy structure, including the height of the residential structure, the maximum height of the solar or small wind energy system, and the height of all other structures located on the property;
b. 
The location and type of screening for proposed ground-mounted solar energy systems;
c. 
All existing and proposed easements/rights-of-way on the site;
d. 
Specific structure setbacks in accordance with the structure setbacks established in the governing zoning district;
e. 
For small wind energy systems, the applicant shall have the burden of proving the shadow flicker will not have significant adverse impact on neighboring or adjacent uses. Potential shadow flicker will be addressed either through siting or mitigation measures; and
f. 
Any other information as required by the City of Chesterfield.
[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
Decisions of the Director of Planning regarding the application of this Article may be appealed to the Board of Adjustment in accordance with applicable procedures as established by the Board of Adjustment.
[CC 1990 § 7-21; Ord. No. 2760, 9-9-2013]
A. 
Solar, ground source heat pump and small wind energy systems lawfully installed and operable on residential property, prior to the effective date of this Article of the City Code, are exempt from the requirements herein unless:
1. 
The solar, ground source heat pump or small wind energy system is moved to another location on the property, enlarged, or replaced with a new system; or
2. 
Any other work or alteration is done to the existing solar, ground source heat pump or small wind energy system that requires municipal zoning approval by the City.