Type of Dwelling Unit
|
Minimum Unit Size
(square feet)
|
Lot Area For Dwelling Unit
(square feet)
|
Parking Spaces per Dwelling Unit
| |
---|---|---|---|---|
Efficiency
|
300
|
12,000
|
2.00
| |
1 bedroom
|
400
|
16,000
|
2.00
| |
2 bedrooms
|
500
|
20,000
|
2.00
| |
3 bedrooms
|
600
|
24,000
|
2.00
| |
4 bedroom
|
700
|
28,000
|
2.25
|
Use: Single-Family Detached Dwellings
| |
---|---|
Minimum Lot Area (square feet)
|
4,000
|
Minimum Lot Width
|
40 feet
|
Maximum Lot Coverage
|
75%
|
Minimum Front Yard
|
10 feet
|
Minimum Side One Side
|
5 feet
|
Minimum Yard (both sides)
|
10 feet
|
Minimum Rear Yard
|
15 feet
|
Maximum Building Height
|
35 feet
|
Use: Single-Family Semi-Detached Dwellings (Twins)
| |
---|---|
Minimum Lot Area (square feet)
|
3,000
|
Minimum Lot Width
|
30 feet
|
Maximum Lot Coverage
|
85%
|
Minimum Front Yard
|
10 feet
|
Minimum Side One Side
|
0 feet (common lot line)
|
Minimum Yard (both sides)
|
5 feet (opposite common lot line)
|
Minimum Spacing between Principal Buildings
|
15 feet
|
Minimum Rear Yard
|
10 feet
|
Maximum Building Height
|
35 feet
|
Use: Single-Family Attached Dwellings (Townhouses)
| |
---|---|
Minimum Lot Area (square feet)
|
1,000
|
Minimum Lot Width
|
20 feet
|
Maximum Lot Coverage
|
85%
|
Minimum Front Yard
|
10 feet
|
Minimum Side (common lot line)
|
0 feet
|
Minimum Side Yard (end unit)
|
5 feet
|
Rear Yard Setback
|
5 feet
|
Minimum Setback from Alleyway Cartway
|
5 feet
|
Minimum Setback from Curbline of Parking Lot
|
15 feet
|
Maximum Building Height
|
35 feet
|
Minimum Spacing between Principal Buildings
|
10 feet
|
Maximum Number of Dwelling Units in a Building
|
8
|
Use: Multifamily Dwellings
| |
---|---|
Maximum Coverage of Development Site
|
75%
|
Minimum Setback from Road Cartway
|
25 feet
|
Minimum Setback from Curbline of Parking Lot
|
15 feet
|
Maximum Building Height
|
2 stories and 35 feet
|
Minimum Spacing between Principal Buildings
|
15 feet
|
Maximum Number of Dwelling Units in a Building
|
24
|
Use: Dwelling in Combination and Nonresidential Uses
| |
---|---|
Maximum Coverage of Development Site
|
Not applicable to existing barns and other existing buildings
and structures.
|
Minimum Setback from Road Cartway
|
Existing barns and other existing buildings and structures will
maintain existing setbacks from edge of paving.
|
Minimum Setback from Curbline of Parking Lot
|
Existing barns and other existing buildings and structures will
maintain existing setbacks from edge of paving.
|
Maximum Building Height
|
35 feet, with the exception of existing barns and other existing
buildings and structures, and there shall be no routine human occupancy
in any areas above 35 feet.
|
Minimum Spacing between Principal Buildings
|
Existing barns and other existing buildings and structures will
maintain existing minimum spacing between existing principal buildings.
|
Mini-Market Gross Floor Area
|
Maximum Number of Fuel Pumps
|
Maximum Number of Fueling Positions
| |
---|---|---|---|
Less than 4,000 square feet
|
4
|
8
| |
4,000 square feet to 5,000 square feet
|
5
|
10
| |
5,000 square feet to 6,000 square feet
|
6
|
12
| |
6,000 square feet to 8,000 square feet
|
7
|
14
| |
8,000 square feet to 10,000 square feet
|
8
|
16
|