[Added 5-18-2017 by Ord. No. O-17-01]
The tract of land proposed for a halfway house/rehabilitation center must meet the following minimum requirements:
A. 
It shall be located in the Rural Residential (RR), Multifamily Residential (R-3), or General Commercial (C-1) Zoning Districts;
B. 
It must have direct access to either a primary or secondary arterial or collector street as designated in § 177-34A;
C. 
No portion of the proposed structure including any of its accessory structures/uses shall be located closer than 500 feet to an existing residential use, place of assembly, park, or similar recreation space, primary or secondary school, child or adult day-care. This distance shall be measured from the structure to the property line of the nearest aforementioned use(s).
D. 
No portion of the proposed structure including any of its accessory structures/uses shall be located closer than 1,000 feet to an existing correctional facility.
The minimum lot size and width, minimum yard setbacks, maximum lot coverage, and maximum height for halfway houses shall be as follows.
A. 
Minimum lot size. The minimum lot size shall be based upon the following zoning districts.
(1) 
Rural Residential: five acres.
(2) 
Multifamily Residential (R-3): one acre.
(3) 
General Commercial (C-1): The minimum lot size shall be determined on the basis of the minimum width, maximum coverage, yard setback, parking, and other requirements contained in Chapter 200, Zoning.
B. 
Minimum lot width: 150 feet.
C. 
Minimum setbacks.
(1) 
Front and side yard setbacks: 50 feet.
(2) 
Rear yard setbacks: 75 feet.
D. 
Maximum impervious lot coverage. The maximum impervious lot coverage shall not exceed the following based upon the zoning districts in which the halfway house is proposed.
(1) 
Rural Residential (RR): 10% for buildings and 30% in total for all impervious surfaces.
(2) 
Multifamily Residential (R-3): 50% for all impervious surfaces.
(3) 
General Commercial (C-1): 30% for buildings and 70% in total for all impervious surfaces.
E. 
Maximum building height: 35 feet.
A. 
One parking space per two persons based on maximum design capacity. Additional spaces may be required by College Township as condition of approval dependent upon specific needs of the facility.
B. 
The halfway house shall provide residency for no more than 15 residents at any given time.
C. 
Supervision shall be provided in accordance with the regulations of the certifying agency(ies). College Township may require supervision in cases where none is required by a certifying agency as a condition of approval dependent upon specific needs of the operation.