[Amended 9-8-1993 by Ord. No. 452; 12-8-1993 by Ord. No. 454]
A. 
No encroachment, alteration or improvement of any kind shall be made to any watercourse until all adjacent municipalities which may be affected by such action have been notified by the Borough and until all required permits or approvals have been first obtained from the Pennsylvania Department of Environmental Protection. In addition, the Federal Insurance Administrator and Pennsylvania Department of Community and Economic Development, Bureau of Community Planning, shall be notified by the Borough prior to any alteration or relocation of any watercourse.
B. 
Any new construction, development, uses or activities allowed within any identified floodplain area shall be undertaken in strict compliance with the provisions contained in this chapter and any other applicable codes, ordinances and regulations.
C. 
With any FW (Floodway Area), the following provisions apply:
[Added 12-9-2009 by Ord. No. 504]
(1) 
Any new construction, development, use, activity or encroachment that would cause any increase in flood heights shall be prohibited.
(2) 
No new construction or development shall be allowed, unless a permit is obtained from the Department of Environmental Protection Regional Office.
[Amended 9-8-1993 by Ord. No. 452; 12-8-1993 by Ord. No. 454]
A. 
Within any identified floodplain area, the elevation of the lowest floor (including basement) of any new or substantially improved residential structure shall be 11/2 feet or more above the one-hundred-year-flood elevation. Enclosed areas below the lowest floor (including basement) are prohibited.
B. 
Within any identified floodplain area, the elevation of the lowest floor (including basement) of any new or substantially improved nonresidential structure shall be 11/2 feet or more above the one-hundred-year-flood elevation or to be floodproofed up to that height. Any nonresidential structure or part thereof having a lowest floor (including basement) which is not elevated to at least 11/2 feet above the one-hundred-year-flood elevation shall be floodproofed in a completely or essentially dry manner in accordance with the W1 or W2 space classification standards contained in the publication entitled "Flood-Proofing Regulations," published by the United States Army Corps of Engineers (June 1972, as amended March 1992), or some other equivalent standard. All plans and specifications for such floodproofing shall be accompanied by statements certified by a registered professional engineer or architect which state that the proposed design and methods of construction are in conformance with the above-referenced standards. Enclosed areas below the lowest floor (including basement) are prohibited.
[Amended 2-13-2002 by Ord. No. 481]
C. 
Partially enclosed space below the lowest floor (including basement) which will be used solely for the parking of a vehicle, building access or incidental storage in an area other than a basement shall be designed and constructed to allow for the automatic entry and exit of floodwaters for the purpose of equalizing hydrostatic forces on exterior walls. The term “partially enclosed space” also includes crawl spaces. Designs for meeting this requirement must either be certified by a registered professional engineer or architect, or meet or exceed the following minimum criteria:
[Added 12-9-2009 by Ord. No. 504]
(1) 
A minimum of two openings having a net total area of not less than one square inch for every square foot of enclosed space.
(2) 
The bottom of all openings shall be no higher than one foot above grade.
(3) 
Openings may be equipped with screens, louvers, etc., or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters.
[Amended 12-8-1993 by Ord. No. 454]
The following minimum standards shall apply for all construction and development proposed within any identified floodplain area.
A. 
Fill. If fill is used, it shall:
(1) 
Extend laterally at least 15 feet beyond the building line from all points.
(2) 
Consist of soil or small rock materials only. Sanitary landfills shall not be permitted.
(3) 
Be compacted to provide the necessary permeability and resistance to erosion, scouring or settling.
(4) 
Be no steeper than one vertical to two horizontal feet unless substantiated data justifying steeper slopes are submitted to and approved by the Building Official.
(5) 
Be used to the extent to which it does not adversely affect adjacent properties.
B. 
Drainage facilities. Storm drainage facilities shall be designed to convey the flood of stormwater runoff in a safe and efficient manner. The system shall ensure proper drainage along streets and provide positive drainage away from buildings. The system shall also be designed to prevent the discharge of excess runoff onto adjacent properties.
C. 
Water and sanitary sewer facilities and systems.
(1) 
All new or replacement water and sanitary sewer facilities and systems shall be located, designed and constructed to minimize or eliminate flood damages and the infiltration of floodwaters.
(2) 
Sanitary sewer facilities and systems shall be designed to prevent the discharge of untreated sewage into floodwaters.
(3) 
No part of any on-site sewage system shall be located within any identified floodplain area except in strict compliance with all state and local regulations for such systems. If any such system is permitted, it shall be located so as to avoid impairment to it or contamination from it during a flood.
D. 
Other utilities. All other utilities such as gas lines, electrical and telephone systems shall be located, elevated (where possible) and constructed to minimize the chance of impairment during a flood.
E. 
Streets. The finished elevation of all new streets shall be no more than one foot below the regulatory flood elevation.
F. 
Storage. All materials that are buoyant, flammable, explosive or, in times of flooding, could be injurious to human, animal or plant life, and not listed in § 137-27, Development which may endanger human life, shall be stored at or above the regulatory flood elevation and/or floodproofed to the maximum extent possible.
G. 
Placement of buildings and structures. All building and structure shall be designed, located and constructed so as to offer the minimum obstruction to the flow of water and shall be designed to have a minimum effect upon the flow and height of floodwater.
H. 
Anchoring.
(1) 
All buildings and structures shall be firmly anchored in accordance with accepted engineering practices to prevent flotation, collapse or lateral movement.
(2) 
All air ducts, large pipes, storage tanks and other similar objects or components located below the regulatory flood elevation shall be securely anchored or affixed to prevent flotation.
I. 
Floor, walls and ceilings.
(1) 
Wood flooring used at or below the regulatory flood elevation shall be installed to accommodate a lateral expansion of the flooring, perpendicular to the flooring grain, without causing structural damage to the building.
(2) 
Plywood used at or below the regulatory flood elevation shall be of a marine or water-resistant variety.
(3) 
Walls and ceilings at or below the regulatory flood elevation shall be designed and constructed of materials that are water-resistant and will withstand inundation.
(4) 
Windows, doors and other components at or below the regulatory flood elevation shall be made of metal or other water-resistant material.
J. 
Paints and adhesives.
(1) 
Paints or other finishes used at or below the regulatory flood elevation shall be of marine or water-resistant quality.
(2) 
Adhesives used at or below the regulatory flood elevation shall be of a marine or water-resistant variety.
(3) 
All wooden components (doors, trim, cabinets, etc.) shall be finished with a marine or water-resistant paint or other finishing material.
K. 
Electrical components.
(1) 
Electrical distribution panels shall be at least three feet above the one-hundred-year-flood elevation.
(2) 
Separate electrical circuits shall serve lower levels and shall be dropped from above.
L. 
Equipment. Water heaters, furnaces, air-conditioning and ventilating units and other electrical, mechanical or utility equipment or apparatus shall not be located below the regulatory flood elevation.
M. 
Fuel supply systems. All gas and oil supply systems shall be designed to prevent the infiltration of floodwaters into the system and discharges from the system into floodwaters. Additional provisions shall be made for the drainage of these systems in the event that the floodwater infiltration occurs.
[Amended 9-8-1993 by Ord. No. 452; 12-8-1993 by Ord. No. 454]
A. 
Within any FW (Floodway Area), manufactured homes shall be prohibited.
B. 
Within any FA (General Floodplain Area), manufactured homes shall be prohibited within the area measured 50 feet landward from the top-of-bank of any watercourse.
[Amended 2-13-2002 by Ord. No. 481]
C. 
Where permitted within any identified floodplain area, all manufactured homes, and any additions thereto, shall be:
(1) 
Placed on a permanent foundation.
(2) 
Elevated so that the lowest floor of the manufactured home is 11/2 feet or more above the elevation of the one-hundred-year flood.
(3) 
Anchored to resist flotation, collapse or lateral movement.