[Ord. No. 8.465 (2645) §2, 8-18-2016; Ord.
No. 14.541 (Bill No. 2761), 12-19-2019; Ord. No. 14.559 (Bill No. 2832), 7-21-2022]
This provision shall apply to an existing private street or
privately maintained street.
[Ord. No. 8.465 (2645) §2, 8-18-2016; Ord.
No. 14.541 (Bill No. 2761), 12-19-2019; Ord. No. 14.559 (Bill No. 2832), 7-21-2022]
A. Before an existing private street or privately maintained street
can be accepted for public maintenance it shall meet the following
minimum requirements:
1.
In areas identified by the Public Works Director, existing street
pavement will be excavated and replaced with a new rock and asphalt
base mix pavement or concrete pavement as appropriate.
2.
If the Public Works Director determines that the street surface
is not in an acceptable condition, a new ultra-thin asphalt-wearing
surface or Type C asphalt overlay will be required.
3.
Appropriate street signage will be installed.
4.
One side of the street will be designated "No Parking" if required
by existing standards.
5.
A minimum pavement width of twenty (20) feet will be in place
or constructed with adequate easements or new right-of-way granted
to allow for City maintenance.
6.
Streets with no ending cul-de-sac will provide for a street-ending
T-section.
7.
Although the installation of new stormwater systems will not
be required unless the Public Works Director determines that the proposed
street improvements will increase existing stormwater drainage concerns,
in which case appropriate stormwater control measures will be installed,
any existing stormwater system will be repaired or replaced to a condition
that allows it to operate normally, as determined by the Public Works
Director.
8.
Although the installation of new sidewalks will not be required
unless it is necessary to complete an existing partially finished
sidewalk system, any existing sidewalks will be repaired to a condition
that allows public use without hazard and/or ensures compliance with
all federal and State requirements as determined by the Public Works
Director in conformance with the standard specifications.