[1]
Cross References — Litter and nuisances, ch. 225; building codes, §§500.050 et seq.; property maintenance code, §§500.140500.150; sewers, ch. 705; utilities, ch. 700; zoning, ch. 400; subdivisions, ch. 410.
[Ord. No. 1959 §2, 1-21-1997; Ord. No. 2250 §1, 11-6-2001; Ord. No. 2543 §§1 — 3, 2-20-2007; Ord. No. 3011, 8-1-2017; Ord. No. 3351, 12-20-2022]
A certain document, copies of which are on file in the office of the City Clerk of the City of Pacific, being marked and designated as the 2018 International Plumbing Code as published by the International Code Council, is hereby adopted as the Plumbing Code of the City of Pacific and the terms of said Plumbing Code are hereby referred to, adopted and made a part hereof as if fully set out in this Section with the additions, insertions, deletions and changes, if any, described in Section 500.100.
[Ord. No. 1959 §2, 1-21-1997; Ord. No. 2250 §2, 11-6-2001; Ord. No. 2543 §§1 — 2, 4, 2-20-2007; Ord. No. 3011, 8-1-2017; Ord. No. 3351, 12-20-2022]
The following Sections of the International Plumbing Code, 2018 Edition, are hereby revised as follows:
1. 
101.1 Title: Insert: These regulations shall be known as "the Plumbing Code of the City of Pacific, Missouri," hereinafter referred to as "this code."
2. 
106.5.3 Expiration: Change: every permit issued shall become invalid after three hundred sixty-five (365) days of issuance. The Code Official is authorized to grant, in writing, one (1) or more extensions of time for a period not more than one hundred eighty (180) days each. The extension shall be requested in writing and justifiable cause demonstrated.
3. 
106.6.2 Fee Schedule: Insert: The fees for mechanical work shall be paid in accordance with the schedule of fees as established by City of Pacific ordinance.
4. 
106.6.3 Fee Refunds: Delete in its entirety.
5. 
108.4 Violation Penalties: Delete in its entirety and add the following: Any person who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter or repair plumbing work in violation of the approved construction documents or directive of the Code Official, or of a permit or certificate issued under the provisions of this code, shall be guilty of an ordinance violation and is punishable as provided in Section 100.170 of the Code of Ordinances of the City of Pacific. Each day that the violation continues shall be deemed a separate offense.
6. 
108.5 Stop Work Orders: Delete in its entirety and add the following: Upon notice from the Code Official, work on any plumbing system that is being done contrary to the provisions of this code or in a dangerous or unsafe manner shall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, or the owner's agent, or to the person doing the work. The notice shall state the condition under which work is authorized to resume. Where an emergency exists as determined by the Code Official, the Code Official shall not be required to give a written notice prior to stopping of work. Any person who shall continue any work in or about the structure after be served a stop work order, except such work as the person is directed to perform to remove a violation or unsafe condition, shall be guilty of an ordinance violation punishable as provided in Section 100.170 of the Code of Ordinances of the City of Pacific.
7. 
109.2 Membership of Board: Delete in its entirety and add the following: The Board of Appeals shall consist of the Board of Adjustment.
8. 
305.6.1 Sewer Depth: Delete in its entirety and add the following: All building sewers shall be a minimum depth of thirty (30) inches (76 cm) below grade.
9. 
602.3 Individual Water Supply: add the following new Subsections:
Expanding or Creating of New Wells Prohibited: Drilling, digging, enlarging or deepening of water wells or reopening of abandoned water wells within the boundaries of the City, except by the City, is hereby prohibited unless approved by the Board of Aldermen.
Use of Water from Sources Outside of the City Prohibited: The use within the limits of the City of water taken from wells and other sources outside of the limits of the City, by any person or entity other than the City, is hereby prohibited unless approved by the Board of Aldermen.
However, no provision hereof shall be deemed to apply the use of bottled water for human consumption. 2009 Amendment
10. 
603.2 Separation of Water Service and Building Sewers: Delete exception #2.
11. 
605.3 Water Service Pipe: Table 605.3 Delete the following:
Acrylonitrile butadiene styrene (ABS) plastic pipe
Asbestos-cement pipe
Chlorinated polyvinyl chloride (CPVC) plastic pipe
Galvanized steel pipe
Polyethylene/aluminum/polyethylene (PE-AL-PE) pipe
Polypropylene (PP) plastic pipe or tubing
Polyvinyl chloride (PVC) plastic pipe
12. 
605.4 Water Distribution Pipe: Table 605.4 Delete the following:
Chlorinated polyvinyl chloride (CPVC) plastic pipe and tubing
Galvanized steel pipe
Polyethylene/aluminum/polyethylene (PE-AL-PE) composite pipe
Polypropylene (PP) plastic pipe or tubing
13. 
608.16.5 Connections to Lawn Irrigation Systems: Delete in its entirety and add the following: The potable water supply to lawn irrigation systems shall be protected against backflow by a reduced pressure principal backflow preventer. Where chemicals are introduced into the system, the potable water supply shall be protected against backflow by a reduced pressure principal backflow preventer.
14. 
608.17 Protection of Individual Water Supplies: Delete in its entirety, (Sections 608.17 through 608.17.8).
15. 
701.2.1 Private Sewage Disposal: Private sewage disposal shall not be allowed except as approved by the Board of Aldermen.
16. 
702.1 Above-ground Drainage and Vent Pipe: Table 702.1 Delete the following:
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including schedule 40, DR22 (PS200) and DR 24 (PSI 40); with a solid, cellular core or composite wall
Polyolefin pipe
Polyvinyl chloride (PVC) plastic pipe DR 22 (PS200) and DR24 (PS140); with a cellular core, or composite wall
Polyvinyl chloride (PVC) plastic pipe with a three and twenty-five hundredths (3.25) inch O.D. and a solid, cellular or composite wall
17. 
702.2 Underground Table 702.3 Delete the following: Drainage and Vent Pipe:
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including schedule 40, DR22 (PS200) and DR24 (PSI40): with a solid, cellular core, or composite wall
Asbestos - cement pipe
Polyolefin pipe
Polyvinyl chloride (PVC) plastic pipe DR22 (PS200) and DR24 (PS140); with a cellular core, or composite wall
Polyvinyl chloride (PVC) plastic pipe with a 3.25 in O.D. and a solid, cellular core, or composite wall
18. 
702.3 Building Sewer Pipe: Table 702.3 Delete the following:
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including schedule 40, DR22 (PS200) and DR24 (PS140): with a solid, cellular core, or composite wall
Acrylonitrile butadiene styrene (ABS) plastic pipe in sewer and drain diameters, including PS35, (PS45), PS50, PS 100, PS140, SDR 23.5 (PS150), and PS200 in solid, cellular core or composite wall
Asbestos-cement pipe
Concrete pipe
Polyvinyl chloride (PVC) plastic pipe DR22 (PS200) and DR24 (PS140); with a cellular core, or composite wall
Polyvinyl chloride (PVC) plastic pipe SDR 42 (PS20), PS35, SDR 35 (PS45), PS50, PS100, PS140, SDR 23.5 (PS150) and PS200; with a cellular core or composite wall
Polyvinyl chloride (PVC) plastic pipe 3.25 in O.D. with a solid, cellular core or composite wall Vitrified clay pipe
19. 
702.4 Pipe Fittings: Table 702.4 Delete the following:
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters
Acrylonitrile butadiene styrene (ABS) plastic pipe in sewer and drain diameters
Asbestos-cement
Polyolefin (PVDF) plastic pipe
Polyvinyl chloride (PVC) plastic pipe 3.25 in O.D. with a solid, cellular core or composite wall
Vitrified clay pipe
20. 
903.1 Roof Extension: Insert: All open vents shall extend through the roof at least twelve (12) inches (305 mm) above roof except that where a roof is to be used for any purpose other than weather protection, the vent extension shall be run at least seven (7) feet (2,134 mm) above the roof.
21. 
918.1 Air Admittance Valves General: Delete in its entirety and add the following: Vent systems utilizing air admittance valves shall comply with this Section. Individual and branch type air admittance valves shall conform to ASSE 1050 & 1051. Air admittance valves shall only be allowed in remodeling or modification of plumbing system where the vent cannot be tied into the existing venting system or terminate to the outside.
22. 
1113.5 Discharge: All sump pump piping shall be discharged to daylight unless approved by the Code Official. Discharge to sanitary sewers is prohibited.