"J.
|
Conduct a minimum of two density tests per manhole section or
pipeline. Conduct one test in the lower half of the trench and one
test in the upper half of the trench at locations as directed by the
Engineer during backfilling operations."
|
"f.
|
Television inspection shall be completed by the Developer/Contractor
prior to acceptance of the line and/or placement of the bituminous
wearing course. During the eighteen-month of the warranty period,
perform a second televised inspection."
|
"c.
|
Color Video Camera: Specifically designed and constructed for
this application.
| ||
1.
|
Camera, Television Monitor, and Other Components: Capable of
producing a minimum 700-line resolution color video picture.
| ||
2.
|
Pan and tilt type, capable of turning at right angles to pipe's
axis over an entire vertical circle (minimum pan of 270° and rotation
of 360°).
| ||
3.
|
Lighting: Suitable to allow clear picture of entire inner pipe
wall extending at least 10 feet in front, including black High-Density
Polyethylene (HDPE) pipe.
| ||
4.
|
Operative in 100% humidity conditions.
| ||
5.
|
Image: Capable of self-righting itself.
| ||
6.
|
Include data view display feature capable of showing on tape
following information.
| ||
a.
|
Lateral addresses.
| ||
b.
|
City and state.
| ||
c.
|
Date and time.
| ||
d.
|
Project name.
| ||
e.
|
Developer's name.
| ||
f.
|
Inside pipe diameter and type.
| ||
g.
|
Manhole identification (upstream manhole to downstream manhole).
| ||
h.
|
On-going footage counter accurate within 0.2 foot.
| ||
i.
|
Include operator narration, in format approved by Borough, using
Borough approved terminology.
| ||
j.
|
Recording of single section of sewer onto 2 DVD/CD-ROMs will
not be acceptable.
| ||
k.
|
Clearly label each DVD/CD-ROM as approved by the Borough.
| ||
7.
|
Mounting: Mounted on tread tractor that moves through sewers."
|
"6.
|
POST-INSTALLATION SURVEY - Television inspection shall be completed
by the Developer/Contractor prior to acceptance of the line and/or
placement of the bituminous wearing course. During the eighteen-month
of the warranty period, perform a second televised inspection.
| ||||||
1.
|
Procedure:
| ||||||
a.
|
CCTV:
| ||||||
i.
|
Mainline:
| ||||||
1.
|
Before TV inspection work, inspect sanitary sewer line from
manhole to manhole, preferably upstream to downstream, one section
at a time.
| ||||||
2.
|
Maintain sanitary sewer main isolation by plugging or bypass
pumping while camera is moving and recording if depth of flow in sewer
requires isolation.
| ||||||
a.
|
Plugs: Secured to remain in place during inspection.
| ||||||
b.
|
Conduct operations to prevent building backups and sewer overflows.
| ||||||
c.
|
Be responsible for cleanup, repair, fines, property damage costs
and claims for any sewage backup, bypass spillage or sanitary sewer
overflow.
| ||||||
b.
|
Placement of Camera:
| ||||||
i.
|
Manhole:
| ||||||
1.
|
Place at center of manhole and commence video before entering
pipe.
| ||||||
2.
|
Start footage counter at center of manhole.
| ||||||
ii.
|
Mainline: Mount on a transport platform that will keep it centered
along longitudinal axis of sewer mainline and above water.
| ||||||
c.
|
Operation of Camera:
| ||||||
i.
|
Show inside of manhole walls, manhole channel, and pipe connection
to wall at both upstream and downstream manhole and lateral connections.
| ||||||
ii.
|
Move through line at speed no greater than 30 feet per minute
stopping for minimum 10 seconds to record lateral connections, mainline
connections, defects, and features and points of interest.
| ||||||
iii.
|
Maintain technical quality, sharp focus, and distortion free
picture.
| ||||||
iv.
|
Videotape a section of sewer in its entirety with no breaks
or interruptions.
| ||||||
v.
|
Pan, tilt, and rotate as necessary to best view and evaluate
lateral connections, defects, features, and points of interest.
| ||||||
vi.
|
Use power winches, powered rewinds, tractors, or other devices
that do not obstruct camera view or interfere with proper documentation
of sewer conditions to move camera through sewer.
| ||||||
1.
|
Whenever non-remote-powered and -controlled winches are used
set up telephones or other suitable means of communication between
manholes to insure good communications.
| ||||||
vii.
|
Use hydraulic jet nozzle if necessary to remove standing water
from line.
| ||||||
viii.
|
Eliminate steam in line for duration of inspection:
| ||||||
1.
|
Utilize blower as needed to defog sewer line.
| ||||||
ix.
|
Measurement for location of defects and service laterals:
| ||||||
1.
|
At ground level by means of Borough's Engineer-approved footage
counter or metering device.
| ||||||
2.
|
Measurement meters: Accurate to 0.2 foot over length of section
being televised.
| ||||||
3.
|
Use measuring target in front of television as exact measurement
reference point.
| ||||||
x.
|
Movement of Television Camera:
| ||||||
1.
|
Mainline:
| ||||||
a.
|
Stop camera at service connections and inspect lateral with
pan and tilt camera.
| ||||||
b.
|
At active service connections where flow is discharging.
| ||||||
i.
|
Identify building address and confirm that laterals are active
by obtaining flush, with or without dye, of property owner's commode
or by using outside cleanout, if available.
| ||||||
ii.
|
If no flows are being discharged from building, consider observed
flow as infiltration/inflow.
| ||||||
xi.
|
Identification of Defects:
| ||||||
1.
|
If roots, sludge, or sediment material impedes inspection withdraw
CCTV equipment and perform inspection from opposite end.
| ||||||
a.
|
Extract camera stuck in sewer line.
| ||||||
b.
|
When additional obstructions are encountered after redeployment
of equipment, and no means are available for passing obstructions,
remand to Borough for resolution.
| ||||||
2.
|
Field Documentation:
| ||||||
a.
|
Mainline:
| ||||||
i.
|
Submit original records, logs, DVDs, CD-ROMs, and electronic
data for sanitary sewer line inspection to Borough within five working
days.
| ||||||
ii.
|
Include, but not be limited to following information.
| ||||||
1.
|
Project number.
| ||||||
2.
|
Basin name.
| ||||||
3.
|
Owner.
| ||||||
4.
|
Date, time (begin to end inspections).
| ||||||
5.
|
Weather condition.
| ||||||
6.
|
Operator name.
| ||||||
7.
|
QA reviewer name.
| ||||||
8.
|
DVD/CD number and index.
| ||||||
9.
|
Address of upper most lateral.
| ||||||
10.
|
Manhole number to manhole number.
| ||||||
11.
|
Manhole depths.
| ||||||
12.
|
Length of pipe segment.
| ||||||
13.
|
Direction of CCTV (upstream or downstream).
| ||||||
14.
|
Pipe size.
| ||||||
15.
|
Pipe material.
| ||||||
16.
|
General physical conditions.
| ||||||
17.
|
Footage locations, clock position, descriptions, and estimated
leakage rates for visible point sources of infiltration/inflow.
| ||||||
18.
|
Footage locations, clock position, and descriptions for lateral
connections and estimated flow from laterals.
| ||||||
19.
|
Footage locations, clock position, and descriptions of defects
such as obstructions, root intrusion, blockages in pipe, deteriorated
joints, offset joints, holes, breaks, cracks, collapses, bends or
sags in alignment, or protruding lateral connections.
| ||||||
20.
|
Footage locations, clock position, and descriptions of other
defects, features and points of interest found.
| ||||||
21.
|
Whether CCTV was complete or incomplete.
| ||||||
22.
|
DVD/CD-ROM Recording/Playback:
| ||||||
a.
|
At same speed that it was recorded.
| ||||||
b.
|
Supply slow motion or stop motion playback features.
| ||||||
c.
|
Once recorded, DVD/CD-ROM becomes property of the Borough.
| ||||||
d.
|
Have DVD/CD-ROM and necessary play-back equipment readily accessible
for review by Borough's Engineer during Project.
| ||||||
23.
|
Observation terminology utilized during audio narration: Follow
the Borough approved terminology.
| ||||||
24.
|
DVD/CD-ROMs displaying poor video quality refers to, but is
not limited to grease or debris on lens, camera under water, image
too dark, washed-out, distorted, or out of focus, lines improperly
cleaned, and poor/no audio.
| ||||||
a.
|
Re-televise line if necessary and resubmit DVD/CD-ROM."
|