A. 
Scope. The provisions of this code shall govern the minimum standards for basic equipment and facilities used for light and ventilation of a structure.
B. 
Alternative methods and devices. In place of the means for natural light and ventilation prescribed in this code, alternative arrangement of windows, louvers, or other devices or methods that will provide the equivalent minimum performance requirements shall be permitted in order to comply with the applicable local building code.
A. 
General. All areas in a structure shall be provided sufficient light so as not to endanger health and safety. All areas in a structure shall be provided with natural light or equipment to accommodate artificial light of sufficient intensity and distributed so as to permit the maintenance of sanitary conditions and the safe use of the area and the appliances, equipment, and fixtures.
B. 
Common halls and stairways. Each common hall and stairway in a structure, other than one- and two-family structures, shall be adequately lighted at all times with an illumination equivalent to the footcandles provided by at least a sixty-watt standard incandescent light bulb for each 200 square feet of floor area, provided that the spacing between lights may not be greater than 30 feet. Each exterior stairway shall be illuminated.
A. 
General. All areas in a structure shall be provided sufficient ventilation so as not to endanger health and safety.
B. 
Mechanical ventilation.
(1) 
When mechanical ventilation is provided instead of natural ventilation, the mechanical ventilating system shall be maintained in good operating condition during the occupancy of the structure or portion of it.
(2) 
When part of the air provided by a mechanical ventilation system is recirculated, the portion or volume of air recirculated may not be recirculated to a different habitable area.