Systems
|
Design Capacity
(years)
|
---|---|
Collection
|
25
|
Culverts under 1/2 square mile drainage area
|
100
|
Detention systems over 1/2 square mile drainage area
|
100
|
Zone
|
Pedestrian Walkway
|
Parking Areas
|
Streets
|
---|---|---|---|
R-1
|
4/0.4
|
5/0.5
|
4/0.4
|
R-2
|
4/0.4
|
5/0.5
|
4/0.4
|
R-3
|
4/0.4
|
5/0.5
|
4/0.4
|
R-4
|
4/0.4
|
5/0.5
|
4/0.4
|
PLC
|
4/0.4
|
5/0.5
|
4/0.4
|
C-1
|
10/0.9
|
16/1.5
|
13/1.2
|
C-2
|
10/0.9
|
16/1.5
|
13/1.2
|
C-3
|
6/0.6
|
16/1.5
|
6/0.6
|
CR
|
6/0.6
|
16/1.5
|
6/0.6
|
SR
|
4/0.4
|
5/0.5
|
4/0.4
|
LI
|
4/0.4
|
11/1.0
|
6/0.6
|
AET
|
6/0.6
|
16/1.5
|
6/0.6
|
CON
|
6/0.6
|
16/1.5
|
6/0.6
|
TC
|
10/0.9
|
20/2.0
|
13/1.2
|
The uses in the following table shall be illuminated at the
levels of the stated zone regardless of the zone the use is located
in.
|
Use
|
Per Zone
|
---|---|
Agriculture/farm
|
R-1
|
Arts center
|
CR
|
Banks, savings and financial offices
|
C-1
|
Bath house/rest rooms
|
CR
|
Beaches
|
CR
|
Bed-and-breakfast
|
R-1
|
Boarding stable
|
CR
|
Child care center
|
C-1
|
Club
|
CR
|
Clubhouse
|
CR
|
Country club
|
CR
|
Dock
|
CR
|
Farm stand/produce
|
CR
|
Golf course
|
CR
|
Health club
|
CR
|
Health services
|
C-2
|
Inn
|
CR
|
Institutional use
|
C-1
|
Multifamily age-restricted housing
|
CR
|
Nature preserve
|
R-1
|
Nursery
|
C-3
|
Office
|
C-3
|
Place of worship
|
C-3
|
Planned adult community
|
CR
|
Professional office
|
C-3
|
Resort-oriented housing
|
CR
|
Restaurant
|
C-1
|
Retail sales
|
C-1
|
Retail sales, outdoor
|
C-1
|
Riding academy/stables
|
CR
|
Specialty food store
|
C-1
|
Specialty shopping center
|
C-2
|
Studio
|
C-1
|
Theater
|
CR
|
Theme park
|
C-1
|
Veterinary hospital
|
C-3
|
Covered Parking Facilities
|
Day
|
Night
|
---|---|---|
General parking and pedestrian access
|
54/5
|
54/5
|
Ramps and corners
|
110/10
|
54/5
|
Entrance areas
|
540/50
|
54/5
|
Lux/footcandles. The levels shown are measured in lux/footcandles.
The minimum standards are based on the level of light that will be
available for new lamps and clean luminaries. When by test or other
means it has been determined that less than 80% of the light specified
in the minimum standards is attained, or a significant number of burnouts
are evident, the owner shall be notified and he will have 30 days
in which to correct the lighting level to the minimum standards.
|
0% to 18%:
|
5,000 s.f. x 1.0
|
= 5,000 s.f. towards MIA
|
18% to 21%:
|
3,000 s.f. x 0.50
|
= 1,500 s.f. towards MIA
|
21% to 24%:
|
12,000 s.f. x 0.33
|
= 4,000 s.f. towards MIA
|
Total MIA:
|
= 10,500 s.f., which complies
|
Additional site protection measures shall be incorporated into
the design, including but not limited to the use of block or rubble
retaining walls, supplemental soil erosion and sediment control techniques,
and phased construction to limit the amount of disturbed area at any
one time. The additional site protection measures must be presented
with and documented on the site or subdivision plans, and are subject
to the review and approval of the Planning or Zoning Board and their
professionals.
|
Table 7.2
| |
---|---|
Zone
|
Minimum Improvable Area
|
R-1
|
10,000
|
R-2
|
9,000
|
R-3
|
7,000
|
R-4
|
6,000
|
PLC
|
6,000
|
CR
|
6,000
|
"S"
|
Sufficient
|
"D"
|
Deficient
|
"O"
|
Omitted
|
"X"
|
Not applicable
|